Experimental determination of physical, chemical and surface properties of biocompatible thermoplastic

The main purpose of this research is determination of physical, chemical and surface properties of thermoplastics, which were certificated for medical employment, for implant or prosthesis manufacturing. The physical and chemical structure of thermoplastics (polyacrylonitrile-co-butadiene-co-styrene, polycarbonate, polyetherimide) were investigated with the Fourier-transform infrared spectroscopy (FTIR), differential thermal and thermogravimetric analysis (DTA/TG), differential scanning calorimetry (DSC), wide-angle X-ray diffraction (XRD) and scanning electron microscopy (SEM). The surface of all investigated thermoplastics had a transition or a hydrophobic state. The contact angle hysteresis by distilled water was in range 95.6–103.0° that indicates sticky wetting behavior of surfaces. The contact angle by blood plasma was in the range 84.7–92.1°, depending on the chemical structure of the thermoplastic polymer. Despite the lower contact angle value of the blood plasma, the amount of its adsorption was greater than in case of distilled water, and it should be considered in development of medical polymer devices.

Publication Details

Journal
Materials Physics and Mechanics
Published
2024-10-17
DOI
https://doi.org/10.18149/10.18149/mpm.5232024_1
Primary Topic
Electrospun Nanofibers in Biomedical Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Experimental determination of physical, chemical and surface properties of biocompatible thermoplastic

Materials Physics and Mechanics
Electrospun Nanofibers in Biomedical Applications
article

Experimental determination of physical, chemical and surface properties of biocompatible thermoplastic

article en

Abstract

The main purpose of this research is determination of physical, chemical and surface properties of thermoplastics, which were certificated for medical employment, for implant or prosthesis manufacturing. The physical and chemical structure of thermoplastics (polyacrylonitrile-co-butadiene-co-styrene, polycarbonate, polyetherimide) were investigated with the Fourier-transform infrared spectroscopy (FTIR), differential thermal and thermogravimetric analysis (DTA/TG), differential scanning calorimetry (DSC), wide-angle X-ray diffraction (XRD) and scanning electron microscopy (SEM). The surface of all investigated thermoplastics had a transition or a hydrophobic state. The contact angle hysteresis by distilled water was in range 95.6–103.0° that indicates sticky wetting behavior of surfaces. The contact angle by blood plasma was in the range 84.7–92.1°, depending on the chemical structure of the thermoplastic polymer. Despite the lower contact angle value of the blood plasma, the amount of its adsorption was greater than in case of distilled water, and it should be considered in development of medical polymer devices.

Materials Physics and Mechanics
Industry, innovation and infrastructure
Openalex Percentile: Top 85%
Electrospun Nanofibers in Biomedical Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.