First experimental results of a R744 water-to-water heat pump for space heating.

The transition towards more sustainable and energy-efficient heating technologies is crucial to mitigate climate change effects. Natural refrigerants have gained attention as environmentally friendly alternatives to traditional refrigerants. CO2 (R744) is a valid alternative because it is both non-toxic and non-flammable and has a low global warming potential. In the present paper, the first findings of an experimental analysis carried out to evaluate the performance of a water-to-water heat pump using R744 as a refrigerant are presented. The heat pump is equipped with a semi-hermetic variable speed compressor, three brazed plate heat exchangers, and an electronic expansion valve to control and optimize the pressure at the gas cooler. The heat pump is tested under various conditions to supply hot water with high ΔT for space heating. The results indicate that the heating capacity ranges from 5.6 kW to around 7.2 kW, and the COP ranges from 2.89 to 4.73.

Publication Details

Journal
Virtual Community of Pathological Anatomy (University of Castilla La Mancha)
Published
2024-12-24
DOI
https://doi.org/10.18462/iir.gl2024.1194
Primary Topic
Refrigeration and Air Conditioning Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

First experimental results of a R744 water-to-water heat pump for space heating.

Virtual Community of Pathological Anatomy (University of Castilla La Mancha)
Refrigeration and Air Conditioning Technologies
article

First experimental results of a R744 water-to-water heat pump for space heating.

article en

Abstract

The transition towards more sustainable and energy-efficient heating technologies is crucial to mitigate climate change effects. Natural refrigerants have gained attention as environmentally friendly alternatives to traditional refrigerants. CO2 (R744) is a valid alternative because it is both non-toxic and non-flammable and has a low global warming potential. In the present paper, the first findings of an experimental analysis carried out to evaluate the performance of a water-to-water heat pump using R744 as a refrigerant are presented. The heat pump is equipped with a semi-hermetic variable speed compressor, three brazed plate heat exchangers, and an electronic expansion valve to control and optimize the pressure at the gas cooler. The heat pump is tested under various conditions to supply hot water with high ΔT for space heating. The results indicate that the heating capacity ranges from 5.6 kW to around 7.2 kW, and the COP ranges from 2.89 to 4.73.

Virtual Community of Pathological Anatomy (University of Castilla La Mancha)
Openalex Percentile: Top 69%
Refrigeration and Air Conditioning Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.