Comprehensive Treatment of Curved Section Abnormal Noise for Elevated Urban Rail Transit Line

[Objective] Problems of vibration and noise during the urban rail transit operation are becoming increasingly prominent. In particular, the wider impact range of elevated line noise has become a hot spot of resident complaints. Therefore, it is necessary to conduct comprehensive treatment research on the abnormal noise from urban rail transit elevated lines to alleviate the disturbance to the residents mainly caused by the "curve squeaking" noise. [Method] Based on the abnormal vibration and noise occurring in the curved section of an elevated metro line in Shenzhen, on-site investigation and environment noise tests are carried out respectively, corresponding treatment measures are implemented. According to the on-site test results before and after the treatment as well as under different working conditions, the noise control effects are obtained through comparative analysis of the results before and after the implementation of different measures. [Result & Conclusion] The rail top coating device has little influence on the overall wheel-rail noise level, but can effectively suppress the squealing noise. Grinding steel rail has significant effect on reducing wheel-rail noise, and the short-wave corrugation in the curved section is eliminated. Optimizing the train driving speed has certain effect on lessening wheel-rail noise, and can avoid the occurrence of rail side wear. Through the comprehensive application of different treatment measures, the peak value of the track-side noise is reduced by 7.4 dB(A), and the equivalent noise value is reduced by 5.9 dB(A). The peak value of the train passing noise detected at residential buildings is reduced to 0.5 dB(A) compared with the background noise, and the equivalent noise value is reduced to 0.3 dB(A). The treatment measures show a remarkable noise reduction effect in that the metro noise contributes little to the environment and the curve squealing noise no longer appears.

Institutions

Publication Details

Journal
SHILAP Revista de lepidopterología
Published
2025-01-01
DOI
https://doi.org/10.16037/j.1007-869x.2025.01.017
Primary Topic
Railway Systems and Energy Efficiency
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comprehensive Treatment of Curved Section Abnormal Noise for Elevated Urban Rail Transit Line

SHILAP Revista de lepidopterología
Railway Systems and Energy Efficiency
article

Comprehensive Treatment of Curved Section Abnormal Noise for Elevated Urban Rail Transit Line

article en

Abstract

[Objective] Problems of vibration and noise during the urban rail transit operation are becoming increasingly prominent. In particular, the wider impact range of elevated line noise has become a hot spot of resident complaints. Therefore, it is necessary to conduct comprehensive treatment research on the abnormal noise from urban rail transit elevated lines to alleviate the disturbance to the residents mainly caused by the "curve squeaking" noise. [Method] Based on the abnormal vibration and noise occurring in the curved section of an elevated metro line in Shenzhen, on-site investigation and environment noise tests are carried out respectively, corresponding treatment measures are implemented. According to the on-site test results before and after the treatment as well as under different working conditions, the noise control effects are obtained through comparative analysis of the results before and after the implementation of different measures. [Result & Conclusion] The rail top coating device has little influence on the overall wheel-rail noise level, but can effectively suppress the squealing noise. Grinding steel rail has significant effect on reducing wheel-rail noise, and the short-wave corrugation in the curved section is eliminated. Optimizing the train driving speed has certain effect on lessening wheel-rail noise, and can avoid the occurrence of rail side wear. Through the comprehensive application of different treatment measures, the peak value of the track-side noise is reduced by 7.4 dB(A), and the equivalent noise value is reduced by 5.9 dB(A). The peak value of the train passing noise detected at residential buildings is reduced to 0.5 dB(A) compared with the background noise, and the equivalent noise value is reduced to 0.3 dB(A). The treatment measures show a remarkable noise reduction effect in that the metro noise contributes little to the environment and the curve squealing noise no longer appears.

SHILAP Revista de lepidopterología
Shenzhen Metro (China) (CN), China Railway Group (China) (CN)
Sustainable cities and communities
Openalex Percentile: Top 47%
Railway Systems and Energy Efficiency
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.