Grounding Fault Protection Scheme for 0.4 kV Switchgear in Metro Substations

[Objective] Single-phase grounding faults account for over 80% of the total distribution line faults, with most inter-phase faults originating from single-phase grounding faults. In metro power distribution systems, failure to promptly isolate single-phase grounding faults in 0.4 kV switchgear may increase the risk of electric shock to personnel and lead to arcs and sparks at the fault site, potentially causing fires and explosions. Therefore, it is essential to thoroughly analyze single-phase grounding fault protection for 0.4 kV switchgear and establish appropriate protective measures. [Method] Based on the characteristics of metro systems and relevant regulatory guidelines, requirements of single-phase grounding fault protection configurations, principle setting, sensitivity coefficient check, and time sequence coordination for 0.4 kV main busbar and 0.4 kV distribution lines are proposed. The protection scheme for grounding faults in 0.4 kV incoming panels is clarified. The typical short-time delay settings for 0.4 kV feeder circuits are clarified. Simplified calculations are performed to determine the maximum cable length for using overcurrent protection as dual-purpose grounding fault protection for 0.4 kV feeders. Principles for grounding fault protection principles and setting criteria are analyzed. [Result & Conclusion] Based on the characteristics of metro systems, the following protection schemes are proposed: using overcurrent protection on the 35 kV high-voltage side to serve as single-phase grounding fault protection for the 0.4 kV main busbar; for single-phase grounding fault protection in 0.4 kV incoming circuits, it is recommended to operate in alarm mode; in the 0.4 kV feeder circuits, prioritize using overcurrent protection as dual-purpose grounding fault protection, and if dual-purpose requirements are not met, zero-sequence overcurrent grounding fault protection is recommended.

Institutions

Publication Details

Journal
SHILAP Revista de lepidopterología
Published
2025-03-01
DOI
https://doi.org/10.16037/j.1007-869x.2025.03.024
Primary Topic
Topic Modeling
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Grounding Fault Protection Scheme for 0.4 kV Switchgear in Metro Substations

SHILAP Revista de lepidopterología
Topic Modeling
article

Grounding Fault Protection Scheme for 0.4 kV Switchgear in Metro Substations

article en

Abstract

[Objective] Single-phase grounding faults account for over 80% of the total distribution line faults, with most inter-phase faults originating from single-phase grounding faults. In metro power distribution systems, failure to promptly isolate single-phase grounding faults in 0.4 kV switchgear may increase the risk of electric shock to personnel and lead to arcs and sparks at the fault site, potentially causing fires and explosions. Therefore, it is essential to thoroughly analyze single-phase grounding fault protection for 0.4 kV switchgear and establish appropriate protective measures. [Method] Based on the characteristics of metro systems and relevant regulatory guidelines, requirements of single-phase grounding fault protection configurations, principle setting, sensitivity coefficient check, and time sequence coordination for 0.4 kV main busbar and 0.4 kV distribution lines are proposed. The protection scheme for grounding faults in 0.4 kV incoming panels is clarified. The typical short-time delay settings for 0.4 kV feeder circuits are clarified. Simplified calculations are performed to determine the maximum cable length for using overcurrent protection as dual-purpose grounding fault protection for 0.4 kV feeders. Principles for grounding fault protection principles and setting criteria are analyzed. [Result & Conclusion] Based on the characteristics of metro systems, the following protection schemes are proposed: using overcurrent protection on the 35 kV high-voltage side to serve as single-phase grounding fault protection for the 0.4 kV main busbar; for single-phase grounding fault protection in 0.4 kV incoming circuits, it is recommended to operate in alarm mode; in the 0.4 kV feeder circuits, prioritize using overcurrent protection as dual-purpose grounding fault protection, and if dual-purpose requirements are not met, zero-sequence overcurrent grounding fault protection is recommended.

SHILAP Revista de lepidopterología
China Railway Fifth Survey and Design Institute Group (CN), China Railway Group (China) (CN), Beijing Survey and Design Institute (China) (CN)
Openalex Percentile: Top 78%
Topic Modeling
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Grounding Fault Protection Scheme for 0.4 kV Switchgear in Metro Substations · SHILAP Revista de lepidopterología (2025) | TGRS Research Map | TGRS