On-Site Measurement and Analysis of the Environmental Vibration of the Elevated Metro Lines with U-shaped Beams under Operating Conditions

[Objective] On-site measurement and analysis of the environmental vibration characteristics are conducted for the elevated metro lines with U-shaped beams under operating conditions. [Method] Taking an elevated metro line with U-shaped beams that has been in operation for 6 years in a certain city as the research object, the impacts of different train speeds, different curve radii and different vibration reduction measures on the track vibration and environmental vibration of the mentioned metro line are analyzed. [Result & Conclusion] When the train speed is between 70 and 90 km/h, for every 10 km/h increase in the train speed, the maximum Z vibration level VLZ,max at the ground strong vibration source increases by approximately 1.1 to 1.4 dB, which is in line with the recommended value of the speed correction term in the environmental impact assessment guidelines. When the line changes from straight to a 800 m radius curve and then to a 400 m one, the vibration acceleration level at the ground strong vibration source will increase by 3.7 to 4.1 dB, and the increase in the Z vibration level is slightly higher than the line correction term of 0.9 to 2.4 dB in the environmental impact assessment guidelines. The vibration reduction fasteners have an impact on the ground vibration in the frequency band from 8 to 200 Hz, the frequency at the location of the maximum difference is 50 Hz, and the vibration acceleration level is reduced by approximately 4.1 dB. The ladder-sleeper ballast bed has an impact on the ground vibration in the frequency band from 4 to 200 Hz, the frequency at the location of the maximum difference is 31.5 Hz, and the vibration acceleration level is reduced by approximately 8.2 dB. Under long-term operating conditions, the ladder-sleeper ballast bed has a better effect on reducing the vibration at the strong ground vibration source than the vibration reduction fasteners, with a wider affecting frequency band.

Institutions

Publication Details

Journal
SHILAP Revista de lepidopterología
Published
2025-05-01
DOI
https://doi.org/10.16037/j.1007-869x.2025.05.034
Primary Topic
Railway Engineering and Dynamics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

On-Site Measurement and Analysis of the Environmental Vibration of the Elevated Metro Lines with U-shaped Beams under Operating Conditions

SHILAP Revista de lepidopterología
Railway Engineering and Dynamics
article

On-Site Measurement and Analysis of the Environmental Vibration of the Elevated Metro Lines with U-shaped Beams under Operating Conditions

article en

Abstract

[Objective] On-site measurement and analysis of the environmental vibration characteristics are conducted for the elevated metro lines with U-shaped beams under operating conditions. [Method] Taking an elevated metro line with U-shaped beams that has been in operation for 6 years in a certain city as the research object, the impacts of different train speeds, different curve radii and different vibration reduction measures on the track vibration and environmental vibration of the mentioned metro line are analyzed. [Result & Conclusion] When the train speed is between 70 and 90 km/h, for every 10 km/h increase in the train speed, the maximum Z vibration level VLZ,max at the ground strong vibration source increases by approximately 1.1 to 1.4 dB, which is in line with the recommended value of the speed correction term in the environmental impact assessment guidelines. When the line changes from straight to a 800 m radius curve and then to a 400 m one, the vibration acceleration level at the ground strong vibration source will increase by 3.7 to 4.1 dB, and the increase in the Z vibration level is slightly higher than the line correction term of 0.9 to 2.4 dB in the environmental impact assessment guidelines. The vibration reduction fasteners have an impact on the ground vibration in the frequency band from 8 to 200 Hz, the frequency at the location of the maximum difference is 50 Hz, and the vibration acceleration level is reduced by approximately 4.1 dB. The ladder-sleeper ballast bed has an impact on the ground vibration in the frequency band from 4 to 200 Hz, the frequency at the location of the maximum difference is 31.5 Hz, and the vibration acceleration level is reduced by approximately 8.2 dB. Under long-term operating conditions, the ladder-sleeper ballast bed has a better effect on reducing the vibration at the strong ground vibration source than the vibration reduction fasteners, with a wider affecting frequency band.

SHILAP Revista de lepidopterología
Tongji University (CN), Beijing Urban Construction Design & Development Group (China) (CN), Haier Group (China) (CN), Guangzhou Metro Group (China) (CN), Qingdao Center of Resource Chemistry and New Materials (CN)
Sustainable cities and communities
Openalex Percentile: Top 57%
Railway Engineering and Dynamics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.