A framework of partial discharge detection for gas-insulated switchgear based on LSTM and multi-head attention

ObjectivesTo achieve long-term stable operation of electrical equipment, a framework for anomaly detection and classification of partial discharge (PD) in gas insulated switchgear (GIS) based on long short-term memory (LSTM) networks and a multi-head attention mechanism was proposed.MethodsFirstly, phase resolved partial discharge (PRPD) analysis was used as the input sequence, and LSTM was employed to learn the temporal correlations in PRPD signals. Then, the results from LSTM were fed into a multi-head attention module. By integrating multi-head self-attention with the LSTM network, the framework focused on different representational subspaces corresponding to different phase sets of PRPD. Secondly, the self-attention mechanism identified important information between input and output sequences, while the multi-head self-attention network captured high-order features of faulty PRPD. Finally, a classification layer was utilized for fault detection in GIS.ResultsThe experimental results were as follows: Linear SVM performed the worst, indicating that traditional machine learning classification algorithms were not effective in capturing subtle differences in the data. CNN+LSTM achieved temporal dependency capture of multivariate time-series data, significantly improving performance over the SVM method. AL+DCNN enhanced the ability to handle dataset imbalances and improved the generality of extracted features through an adversarial learning framework. The proposed method improved the F1 score by 2.96% compared to the AL+DCNN method, demonstrating that combining LSTM with a multi-head attention mechanism could effectively enhance the performance of PD fault identification in GIS. It achieved the best performance in terms of accuracy, recall, and F1 score. This was because the proposed method achieved effective performance complementarity by combining LSTM with the attention network, outperforming other advanced methods in switchgear anomaly detection.ConclusionsThe proposed method could effectively detect PD faults, contributing to ensuring the long-term stable operation of electrical equipment.

Institutions

Publication Details

Journal
SHILAP Revista de lepidopterología
Published
2025-03-01
DOI
https://doi.org/10.16186/j.cnki.1673-9787.2023020042
Primary Topic
High voltage insulation and dielectric phenomena
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A framework of partial discharge detection for gas-insulated switchgear based on LSTM and multi-head attention

SHILAP Revista de lepidopterología
High voltage insulation and dielectric phenomena
article

A framework of partial discharge detection for gas-insulated switchgear based on LSTM and multi-head attention

article en

Abstract

ObjectivesTo achieve long-term stable operation of electrical equipment, a framework for anomaly detection and classification of partial discharge (PD) in gas insulated switchgear (GIS) based on long short-term memory (LSTM) networks and a multi-head attention mechanism was proposed.MethodsFirstly, phase resolved partial discharge (PRPD) analysis was used as the input sequence, and LSTM was employed to learn the temporal correlations in PRPD signals. Then, the results from LSTM were fed into a multi-head attention module. By integrating multi-head self-attention with the LSTM network, the framework focused on different representational subspaces corresponding to different phase sets of PRPD. Secondly, the self-attention mechanism identified important information between input and output sequences, while the multi-head self-attention network captured high-order features of faulty PRPD. Finally, a classification layer was utilized for fault detection in GIS.ResultsThe experimental results were as follows: Linear SVM performed the worst, indicating that traditional machine learning classification algorithms were not effective in capturing subtle differences in the data. CNN+LSTM achieved temporal dependency capture of multivariate time-series data, significantly improving performance over the SVM method. AL+DCNN enhanced the ability to handle dataset imbalances and improved the generality of extracted features through an adversarial learning framework. The proposed method improved the F1 score by 2.96% compared to the AL+DCNN method, demonstrating that combining LSTM with a multi-head attention mechanism could effectively enhance the performance of PD fault identification in GIS. It achieved the best performance in terms of accuracy, recall, and F1 score. This was because the proposed method achieved effective performance complementarity by combining LSTM with the attention network, outperforming other advanced methods in switchgear anomaly detection.ConclusionsThe proposed method could effectively detect PD faults, contributing to ensuring the long-term stable operation of electrical equipment.

SHILAP Revista de lepidopterología
Hefei University of Technology (CN), Jilin Electric Power Research Institute (China) (CN)
Openalex Percentile: Top 65%
High voltage insulation and dielectric phenomena
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines