Simulation Study on the Optimization of Temperature Measurement Cable Layout in Rectangular Warehouse during Ventilation

This study investigated the changes in grain temperature during a seven-day ventilation process in a rectangular warehouse. It also explored the optimization of the cable layout for temperature measurement. Numerical simulation was used to compare the grain temperature monitoring performance of different cable layouts, and their trade-off were evaluated through error and cost analyses. The results showed that the maximum absolute error in temperature monitoring with the national standard cable layout was 0.70 ℃, and the root mean square error was 25.83%. Uniform arrangements with adjusted cable spacing achieved a balance between accuracy and cost. In contrast, heterogeneous layouts reduced the root mean square error of grain temperature monitoring to 22.23%, while further lowering costs. In addition, the study verified the applicability of the heterogeneous layout in warehouses of different sizes. The optimized heterogeneous cable layout shows potential for practical implementation and wider adoption.

Institutions

Publication Details

Journal
SHILAP Revista de lepidopterología
Published
2025-01-01
DOI
https://doi.org/10.16210/j.cnki.1007-7561.2025.01.024
Primary Topic
Food Supply Chain Traceability
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Simulation Study on the Optimization of Temperature Measurement Cable Layout in Rectangular Warehouse during Ventilation

SHILAP Revista de lepidopterología
Food Supply Chain Traceability
article

Simulation Study on the Optimization of Temperature Measurement Cable Layout in Rectangular Warehouse during Ventilation

article en

Abstract

This study investigated the changes in grain temperature during a seven-day ventilation process in a rectangular warehouse. It also explored the optimization of the cable layout for temperature measurement. Numerical simulation was used to compare the grain temperature monitoring performance of different cable layouts, and their trade-off were evaluated through error and cost analyses. The results showed that the maximum absolute error in temperature monitoring with the national standard cable layout was 0.70 ℃, and the root mean square error was 25.83%. Uniform arrangements with adjusted cable spacing achieved a balance between accuracy and cost. In contrast, heterogeneous layouts reduced the root mean square error of grain temperature monitoring to 22.23%, while further lowering costs. In addition, the study verified the applicability of the heterogeneous layout in warehouses of different sizes. The optimized heterogeneous cable layout shows potential for practical implementation and wider adoption.

SHILAP Revista de lepidopterología
Shandong University (CN), University of Jinan (CN)
Openalex Percentile: Top 53%
Food Supply Chain Traceability
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Simulation Study on the Optimization of Temperature Measurement Cable Layout in Rectangular Warehouse during Ventilation · SHILAP Revista de lepidopterología (2025) | TGRS Research Map | TGRS