An AGC Frequency Control Reserve Capacity Evaluation Method for Air Conditioner Groups Based on Nonintrusive Load Disaggregation

Massive air-conditioner resources on the consumer side have a huge potential to be involved in system frequency control, and massive scattered individual air-conditioners can be aggregated into air-conditioner groups to participate in system automatic generation control (AGC). As the operating status of individual air-conditioners is random, it is necessary to accurately evaluate the frequency control reserve capacity of air-conditioner groups. In this paper, a data-driven nonintrusive load disaggregation (NILD) method is proposed to incorporate massive air-conditioner groups into AGC frequency control reserve. First, the proposed method constructs a sequence-to-sequence model to nonintrusively forecast the frequency control reserve capacity of individual air-conditioners. Considering the fact that the participation of air-conditioners in AGC may affect the comfort of users, the feasibility of individual air-conditioners is evaluated to participate in AGC frequency control and a selection mechanism is constructed to determine whether they can be included in the frequency control reserve of air-conditioner groups. In the proposed method, individual air-conditioners within a sub-station that participate in AGC are aggregated to derive the air-conditioner group frequency control reserve of the sub-station, and the air-conditioner group frequency control reserve of all sub-stations are aggregated to derive the entire air-conditioner group frequency control reserve. The experiments simulate different degrees of system frequency drops in which air-conditioner groups work cooperatively with thermal units for AGC frequency control. The simulation results demonstrate the validity of the proposed method.

Institutions

Publication Details

Journal
SHILAP Revista de lepidopterología
Published
2024-12-01
DOI
https://doi.org/10.16183/j.cnki.jsjtu.2023.099
Primary Topic
Frequency Control in Power Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

An AGC Frequency Control Reserve Capacity Evaluation Method for Air Conditioner Groups Based on Nonintrusive Load Disaggregation

SHILAP Revista de lepidopterología
Frequency Control in Power Systems
article

An AGC Frequency Control Reserve Capacity Evaluation Method for Air Conditioner Groups Based on Nonintrusive Load Disaggregation

article en

Abstract

Massive air-conditioner resources on the consumer side have a huge potential to be involved in system frequency control, and massive scattered individual air-conditioners can be aggregated into air-conditioner groups to participate in system automatic generation control (AGC). As the operating status of individual air-conditioners is random, it is necessary to accurately evaluate the frequency control reserve capacity of air-conditioner groups. In this paper, a data-driven nonintrusive load disaggregation (NILD) method is proposed to incorporate massive air-conditioner groups into AGC frequency control reserve. First, the proposed method constructs a sequence-to-sequence model to nonintrusively forecast the frequency control reserve capacity of individual air-conditioners. Considering the fact that the participation of air-conditioners in AGC may affect the comfort of users, the feasibility of individual air-conditioners is evaluated to participate in AGC frequency control and a selection mechanism is constructed to determine whether they can be included in the frequency control reserve of air-conditioner groups. In the proposed method, individual air-conditioners within a sub-station that participate in AGC are aggregated to derive the air-conditioner group frequency control reserve of the sub-station, and the air-conditioner group frequency control reserve of all sub-stations are aggregated to derive the entire air-conditioner group frequency control reserve. The experiments simulate different degrees of system frequency drops in which air-conditioner groups work cooperatively with thermal units for AGC frequency control. The simulation results demonstrate the validity of the proposed method.

SHILAP Revista de lepidopterología
Shanghai Electric (China) (CN)
Openalex Percentile: Top 71%
Frequency Control in Power Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

An AGC Frequency Control Reserve Capacity Evaluation Method for Air Conditioner Groups Based on Nonintrusive Load Disaggregation · SHILAP Revista de lepidopterología (2024) | TGRS Research Map | TGRS