Application of Cathodic Protection on the Outer Wall of Acetylene Wet Gas Cabinet Bell Cover

In response to the tight maintenance schedule of the acetylene wet gas cabinet bell cover at a chemical plant in Inner Mongolia, the subsequent layers of coating were carried out before the previous coatings had fully cured, leading to defects in the coating itself.After longterm operation, phenomena such as cracking and peeling occurred, and the outer wall of the bell cover became severely rusted, even perforated, posing a significant safety hazard.To control the corrosion of the outer wall of gas cabinet bell cover, the magnesium anode and zinc anode were installed in the fixed area in the early stage, and the corrosion rate was tested by hanging corrosion coupons to get the best anti-corrosion effect of magnesium anode.Based on theoretical calculations and the proper arrangement of anodes in the later stage, construction and installation carried out during the maintenance period, and the cathodic protection effect was tested to meet ≤-0.85 V (vs CSE) after the installation was completed.By combining cathodic protection with existing coatings, corrosion on the outer wall of the bell cover was slowed or suppressed,thereby extending its service life.

Institutions

Publication Details

Journal
SHILAP Revista de lepidopterología
Published
2024-09-01
DOI
https://doi.org/10.16577/j.issn.1001-1560.2024.0217
Primary Topic
Corrosion Behavior and Inhibition
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Application of Cathodic Protection on the Outer Wall of Acetylene Wet Gas Cabinet Bell Cover

SHILAP Revista de lepidopterología
Corrosion Behavior and Inhibition
article

Application of Cathodic Protection on the Outer Wall of Acetylene Wet Gas Cabinet Bell Cover

article en

Abstract

In response to the tight maintenance schedule of the acetylene wet gas cabinet bell cover at a chemical plant in Inner Mongolia, the subsequent layers of coating were carried out before the previous coatings had fully cured, leading to defects in the coating itself.After longterm operation, phenomena such as cracking and peeling occurred, and the outer wall of the bell cover became severely rusted, even perforated, posing a significant safety hazard.To control the corrosion of the outer wall of gas cabinet bell cover, the magnesium anode and zinc anode were installed in the fixed area in the early stage, and the corrosion rate was tested by hanging corrosion coupons to get the best anti-corrosion effect of magnesium anode.Based on theoretical calculations and the proper arrangement of anodes in the later stage, construction and installation carried out during the maintenance period, and the cathodic protection effect was tested to meet ≤-0.85 V (vs CSE) after the installation was completed.By combining cathodic protection with existing coatings, corrosion on the outer wall of the bell cover was slowed or suppressed,thereby extending its service life.

SHILAP Revista de lepidopterología
Wuhan Research Institute of Materials Protection (CN)
Openalex Percentile: Top 80%
Corrosion Behavior and Inhibition
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.