A modified Wagner stem design Increases the primary stability in cementless revision hip arthroplasty

Background: Primary stability is of great importance for the longevity of the implant in cementless revision total hip arthroplasty, since instability is a major cause of rerevision. The purpose of this study was to evaluate the effect of an additional set of less prominent, wider splines added to an established conical stem design with sharp splines on axial stability in a model with significant proximal bone defects. Methods: Twenty fresh-frozen human femurs were implanted with either the established or the additional spline design, dynamically loaded and tested in a load-to-failure configuration. Cortical contact in the femoral canal after implantation was evaluated by superimposing computed tomography scans and 3-dimensional laser scans. Stem subsidence and micromotion were evaluated to assess primary stability. Results: Stems remained stable during cyclic loading of up to 200% body weight, except in bones with cortical bone mineral density below 1000 mgHA/mL. A significant reduction of more than 85% in stem subsidence (P =.040), axial micromotion (P =.007), and rotational micromotion (P =.010) was achieved with the new spline design. Load-to-failure testing exceeded 400% body weight. Conclusions: The new spline design increased the cortical contact which resulted in increased axial primary stability in this in vitro experiment. Bone mineral density as a measure of bone quality proved to be a decisive factor for achieving immediate postoperative stability. Further variations of the established stem designs could further improve the longevity of artificial joint replacements.

Publication Details

Journal
TUHH Open Research
Published
2025-02-03
DOI
https://doi.org/10.15480/882.14601
Primary Topic
Orthopaedic implants and arthroplasty
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A modified Wagner stem design Increases the primary stability in cementless revision hip arthroplasty

TUHH Open Research
Orthopaedic implants and arthroplasty
article

A modified Wagner stem design Increases the primary stability in cementless revision hip arthroplasty

article en

Abstract

Background: Primary stability is of great importance for the longevity of the implant in cementless revision total hip arthroplasty, since instability is a major cause of rerevision. The purpose of this study was to evaluate the effect of an additional set of less prominent, wider splines added to an established conical stem design with sharp splines on axial stability in a model with significant proximal bone defects. Methods: Twenty fresh-frozen human femurs were implanted with either the established or the additional spline design, dynamically loaded and tested in a load-to-failure configuration. Cortical contact in the femoral canal after implantation was evaluated by superimposing computed tomography scans and 3-dimensional laser scans. Stem subsidence and micromotion were evaluated to assess primary stability. Results: Stems remained stable during cyclic loading of up to 200% body weight, except in bones with cortical bone mineral density below 1000 mgHA/mL. A significant reduction of more than 85% in stem subsidence (P =.040), axial micromotion (P =.007), and rotational micromotion (P =.010) was achieved with the new spline design. Load-to-failure testing exceeded 400% body weight. Conclusions: The new spline design increased the cortical contact which resulted in increased axial primary stability in this in vitro experiment. Bone mineral density as a measure of bone quality proved to be a decisive factor for achieving immediate postoperative stability. Further variations of the established stem designs could further improve the longevity of artificial joint replacements.

TUHH Open Research
Openalex Percentile: Top 39%
Orthopaedic implants and arthroplasty
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.