Influence Laws of Train Operation Parameters and Bypass Tunnel Parameters on Bypass Tunnel Ventilation Effect in Subway Station Track Zone

[Objective] Due to space constraints, some subway station piston ventilation shafts are set up in the station track zones, and a bypass tunnel is used for connecting the ventilation shaft to the main line tunnel outside the track zone. It is necessary to study the influence laws of train operation parameters and bypass tunnel parameters on the ventilation effect of the bypass tunnel. [Method] A one-dimensional tunnel ventilation network model of a certain line with bypass tunnel is established, and the ventilation effect of the bypass tunnel under different train pair numbers, train velocities and bypass tunnel lengths is simulated and analyzed. [Result & Conclusion] When there is a bypass tunnel, the increase in train pair numbers and train speed can both effectively improve the tunnel piston air volume. When the bypass tunnel is located at the train entrance end, the maximum change value of the tunnel piston air volume increases by 5.2 m3/s and 5.1 m3/s respectively with the increase of train pair numbers and train speed. When the bypass tunnel is located at the exit end, the maximum change value of the tunnel piston air volume increases with train pair numbers and train speed by 11.8 m3/s and 16.7 m3/s respectively, indicating that tunnel piston air volume is more affected in the latter case. When the bypass tunnel is located at the exit end, the tunnel air temperature drops more significantly, and the maximum temperature drop of the tunnel air increases by 1.6 ℃ and 3.5 ℃, respectively, with the increase in train pair numbers and train speed. Changes in bypass tunnel lengths have little effect on the changes in tunnel air volume and air temperature, and the tunnel thermal environment reaches best with a bypass tunnel length of 18 m.

Institutions

Publication Details

Journal
SHILAP Revista de lepidopterología
Published
2025-04-01
DOI
https://doi.org/10.16037/j.1007-869x.2025.04.020
Primary Topic
Aerodynamics and Fluid Dynamics Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Influence Laws of Train Operation Parameters and Bypass Tunnel Parameters on Bypass Tunnel Ventilation Effect in Subway Station Track Zone

SHILAP Revista de lepidopterología
Aerodynamics and Fluid Dynamics Research
article

Influence Laws of Train Operation Parameters and Bypass Tunnel Parameters on Bypass Tunnel Ventilation Effect in Subway Station Track Zone

article en

Abstract

[Objective] Due to space constraints, some subway station piston ventilation shafts are set up in the station track zones, and a bypass tunnel is used for connecting the ventilation shaft to the main line tunnel outside the track zone. It is necessary to study the influence laws of train operation parameters and bypass tunnel parameters on the ventilation effect of the bypass tunnel. [Method] A one-dimensional tunnel ventilation network model of a certain line with bypass tunnel is established, and the ventilation effect of the bypass tunnel under different train pair numbers, train velocities and bypass tunnel lengths is simulated and analyzed. [Result & Conclusion] When there is a bypass tunnel, the increase in train pair numbers and train speed can both effectively improve the tunnel piston air volume. When the bypass tunnel is located at the train entrance end, the maximum change value of the tunnel piston air volume increases by 5.2 m3/s and 5.1 m3/s respectively with the increase of train pair numbers and train speed. When the bypass tunnel is located at the exit end, the maximum change value of the tunnel piston air volume increases with train pair numbers and train speed by 11.8 m3/s and 16.7 m3/s respectively, indicating that tunnel piston air volume is more affected in the latter case. When the bypass tunnel is located at the exit end, the tunnel air temperature drops more significantly, and the maximum temperature drop of the tunnel air increases by 1.6 ℃ and 3.5 ℃, respectively, with the increase in train pair numbers and train speed. Changes in bypass tunnel lengths have little effect on the changes in tunnel air volume and air temperature, and the tunnel thermal environment reaches best with a bypass tunnel length of 18 m.

SHILAP Revista de lepidopterología
Powerchina Huadong Engineering Corporation (China) (CN), Southwest Jiaotong University (CN)
Sustainable cities and communities
Openalex Percentile: Top 47%
Aerodynamics and Fluid Dynamics Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.