Wind-Induced Vibration Response and Weak Locations of 110 kV Diverging Branch Rods Under Strong Wind

[Objective] The cross arms of the diverging branch rods are arranged perpendicularly, with cross-sectional dimensions varying linearly with height. Due to the complexity of structural modeling, corresponding structural analysis has not yet been conducted. [Method] To analyze the wind-induced vibration response and weak locations of diverging branch rods under strong wind conditions, a shell element finite element model was established to obtain its true mode shapes and a simplified beam element finite element model was proposed. Non-structural components were also addressed. The validity of the simplified model is verified by comparing mode shapes and frequencies. Dynamic response analysis under wind attack angles of 90°, 60°, 45°, and 0° were conducted to study the wind-induced vibration response and identify weak locations at various angles. [Result] The study shows that the mode shapes of diverging branch rods are primarily characterized by bending deformation, with negligible influence from torsion. Under a 90° wind reaction angle, the maximum wind-induced displacement at the top of the tower exceeds the relevant specified limits, and the stress at the base of the tower is the highest. Under a 45° wind reaction angle, the displacement at the top of the tower is the smallest, but the stress at the base is second only to that under a 90° wind reaction angle. The 90° wind reaction angle represents the most adverse condition. [Conclusion] The design control parameter for diverging branch rods is the displacement at the top of the tower. Additionally, the stress at the base of the tower is significant and poses a risk. Under different wind attack angles at a design wind speed of 29 m/s, the stability of the diverging branch rods meets the requirements, but the displacement at the top of the tower exceeds the limits. Existing diverging branch rods should be reinforced, while planned constructions can consider reducing span length or increasing cross-sectional area to avoid displacement exceeding limits.

Institutions

Publication Details

Journal
SHILAP Revista de lepidopterología
Published
2025-03-01
DOI
https://doi.org/10.16516/j.ceec.2024-328
Primary Topic
Vibration and Dynamic Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Wind-Induced Vibration Response and Weak Locations of 110 kV Diverging Branch Rods Under Strong Wind

SHILAP Revista de lepidopterología
Vibration and Dynamic Analysis
article

Wind-Induced Vibration Response and Weak Locations of 110 kV Diverging Branch Rods Under Strong Wind

article en

Abstract

[Objective] The cross arms of the diverging branch rods are arranged perpendicularly, with cross-sectional dimensions varying linearly with height. Due to the complexity of structural modeling, corresponding structural analysis has not yet been conducted. [Method] To analyze the wind-induced vibration response and weak locations of diverging branch rods under strong wind conditions, a shell element finite element model was established to obtain its true mode shapes and a simplified beam element finite element model was proposed. Non-structural components were also addressed. The validity of the simplified model is verified by comparing mode shapes and frequencies. Dynamic response analysis under wind attack angles of 90°, 60°, 45°, and 0° were conducted to study the wind-induced vibration response and identify weak locations at various angles. [Result] The study shows that the mode shapes of diverging branch rods are primarily characterized by bending deformation, with negligible influence from torsion. Under a 90° wind reaction angle, the maximum wind-induced displacement at the top of the tower exceeds the relevant specified limits, and the stress at the base of the tower is the highest. Under a 45° wind reaction angle, the displacement at the top of the tower is the smallest, but the stress at the base is second only to that under a 90° wind reaction angle. The 90° wind reaction angle represents the most adverse condition. [Conclusion] The design control parameter for diverging branch rods is the displacement at the top of the tower. Additionally, the stress at the base of the tower is significant and poses a risk. Under different wind attack angles at a design wind speed of 29 m/s, the stability of the diverging branch rods meets the requirements, but the displacement at the top of the tower exceeds the limits. Existing diverging branch rods should be reinforced, while planned constructions can consider reducing span length or increasing cross-sectional area to avoid displacement exceeding limits.

SHILAP Revista de lepidopterología
Central South University (CN), Shanghai Electric (China) (CN)
Affordable and clean energy
Openalex Percentile: Top 49%
Vibration and Dynamic Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.