Closed Loop PID Control of Nasally Administered Oxygen using SpO2 feedback

More than 95% of death in children from preventable or easily treatable diseases happens in developing countries [1]. For children under 5 in that group, pneumonia is the leading cause of death [1]. Oxygen therapy (through a nasal cannula) is an effective therapy for children suffering from pneumonia and other respiratory infections [3]. Hypoxaemia (low blood oxygen levels) is the most prominent cause of death in children suffering from pneumonia [1]. While the WHO recommends oxygen titration to maintain a peripheral oxygen saturation (SpO2) of 90%+ and prevent hypoxaemia, current methods are manual and rarely result in a satisfactory amount of time within SpO2 target limits [2]. Moreover, oxygen is a valuable commodity in most of the world [1] and thus its use should be controlled and limited to only the necessary amount for each patient. This thesis therefore explores the modelling of the SpO2 response to changes in the flow rate of nasally administered oxygen using data collected from a study done in collaboration between the BC Children’s Research Institute and Holy Innocents Hospital, Uganda. The models are then used to inform the design of a PID controller that is tolerant to all the obtained models. This is done by performing constrained optimization over the model set, minimizing the IAE (Integrated Absolute Error) of the error signal for a load step disturbance rejection while limiting the maximum sensitivity Ms to ensure tolerance to modelling errors and inter-patient variability. Finally, the controller is simulated in different scenarios and its performance is evaluated.

Publication Details

Journal
Open Collections
Published
2025-01-01
DOI
https://doi.org/10.14288/1.0448874
Primary Topic
Advanced Control Systems Design
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Closed Loop PID Control of Nasally Administered Oxygen using SpO2 feedback

Open Collections
Advanced Control Systems Design
article

Closed Loop PID Control of Nasally Administered Oxygen using SpO2 feedback

article en

Abstract

More than 95% of death in children from preventable or easily treatable diseases happens in developing countries [1]. For children under 5 in that group, pneumonia is the leading cause of death [1]. Oxygen therapy (through a nasal cannula) is an effective therapy for children suffering from pneumonia and other respiratory infections [3]. Hypoxaemia (low blood oxygen levels) is the most prominent cause of death in children suffering from pneumonia [1]. While the WHO recommends oxygen titration to maintain a peripheral oxygen saturation (SpO2) of 90%+ and prevent hypoxaemia, current methods are manual and rarely result in a satisfactory amount of time within SpO2 target limits [2]. Moreover, oxygen is a valuable commodity in most of the world [1] and thus its use should be controlled and limited to only the necessary amount for each patient. This thesis therefore explores the modelling of the SpO2 response to changes in the flow rate of nasally administered oxygen using data collected from a study done in collaboration between the BC Children’s Research Institute and Holy Innocents Hospital, Uganda. The models are then used to inform the design of a PID controller that is tolerant to all the obtained models. This is done by performing constrained optimization over the model set, minimizing the IAE (Integrated Absolute Error) of the error signal for a load step disturbance rejection while limiting the maximum sensitivity Ms to ensure tolerance to modelling errors and inter-patient variability. Finally, the controller is simulated in different scenarios and its performance is evaluated.

Open Collections
Partnerships for the goals
Openalex Percentile: Top 49%
Advanced Control Systems Design
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Closed Loop PID Control of Nasally Administered Oxygen using SpO2 feedback · Open Collections (2025) | TGRS Research Map | TGRS