S1 Data -

<div><p>Purpose</p><p>Stereopsis, the ability of humans to perceive depth through distinct visual stimuli in each eye, is foundational to autostereoscopic technology in computing. However, ensuring stable head position during assessments has been challenging. This study evaluated the utility of artificial intelligence (AI)-enhanced face tracking technology in overcoming this challenge by ensuring that each eye consistently receives its intended image.</p><p>Methods</p><p>The Lume Pad 2, an autostereoscopic tablet with AI-enhanced face tracking, was utilized to simulate quantitative parts of the Stereo Fly test and TNO Stereotests for contour and random dot stereopsis. The study recruited 30 children (14 males and 16 females, mean age of 9.2 ± 0.3 years, age range of 6–12 years) and 30 adults (10 males and 20 females, mean age of 29.4 ± 1.0 years, age range of 21–42 years) to assess the tablet’s inter-session reliability. Agreement between conventional and the autostereoscopic tablet-simulated stereotests was tested in a larger group of 181 children (91 males and 90 females, mean age of 9.1 ± 0.4 years, age range of 6–12 years) and 160 adults (69 males and 91 females, mean age of 38.6 ± 2.1 years, age range of 21–65 years). Inter-session reliability and agreement were analyzed using weighted Kappa coefficient and non-parametric Bland-Altman analysis.</p><p>Results</p><p>The autostereoscopic tablet demonstrated high inter-session reliability (<i>κ</i> all > 0.80), except for the simulated TNO Stereotest in adults, which demonstrated moderate inter-session reliability (<i>κ</i> = 0.571). Non-parametric Bland-Altman analysis revealed zero median differences, confirming consistent inter-session reliability. Similar patterns were observed in comparing AI-based and conventional methods, with both the weighted Kappa coefficient (<i>κ</i> all > 0.80) and non-parametric Bland-Altman analysis indicating significant agreement. The agreement between methodologies was confirmed by permissible differences, which were smaller than the minimum step range.</p><p>Conclusion</p><p>The integration of AI-based autostereoscopic technology with sub-pixel precision demonstrates significant potential for clinical stereopsis measurements.</p></div>

Publication Details

Journal
Figshare
Published
2024-10-17
DOI
https://doi.org/10.1371/journal.pone.0312153.s001
Primary Topic
Human auditory perception and evaluation
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

S1 Data -

Figshare
Human auditory perception and evaluation
article

S1 Data -

article en

Abstract

<div><p>Purpose</p><p>Stereopsis, the ability of humans to perceive depth through distinct visual stimuli in each eye, is foundational to autostereoscopic technology in computing. However, ensuring stable head position during assessments has been challenging. This study evaluated the utility of artificial intelligence (AI)-enhanced face tracking technology in overcoming this challenge by ensuring that each eye consistently receives its intended image.</p><p>Methods</p><p>The Lume Pad 2, an autostereoscopic tablet with AI-enhanced face tracking, was utilized to simulate quantitative parts of the Stereo Fly test and TNO Stereotests for contour and random dot stereopsis. The study recruited 30 children (14 males and 16 females, mean age of 9.2 ± 0.3 years, age range of 6–12 years) and 30 adults (10 males and 20 females, mean age of 29.4 ± 1.0 years, age range of 21–42 years) to assess the tablet’s inter-session reliability. Agreement between conventional and the autostereoscopic tablet-simulated stereotests was tested in a larger group of 181 children (91 males and 90 females, mean age of 9.1 ± 0.4 years, age range of 6–12 years) and 160 adults (69 males and 91 females, mean age of 38.6 ± 2.1 years, age range of 21–65 years). Inter-session reliability and agreement were analyzed using weighted Kappa coefficient and non-parametric Bland-Altman analysis.</p><p>Results</p><p>The autostereoscopic tablet demonstrated high inter-session reliability (<i>κ</i> all > 0.80), except for the simulated TNO Stereotest in adults, which demonstrated moderate inter-session reliability (<i>κ</i> = 0.571). Non-parametric Bland-Altman analysis revealed zero median differences, confirming consistent inter-session reliability. Similar patterns were observed in comparing AI-based and conventional methods, with both the weighted Kappa coefficient (<i>κ</i> all > 0.80) and non-parametric Bland-Altman analysis indicating significant agreement. The agreement between methodologies was confirmed by permissible differences, which were smaller than the minimum step range.</p><p>Conclusion</p><p>The integration of AI-based autostereoscopic technology with sub-pixel precision demonstrates significant potential for clinical stereopsis measurements.</p></div>

Figshare
Industry, innovation and infrastructure
Openalex Percentile: Top 45%
Human auditory perception and evaluation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.