Design and development of fluorescence gas detector for X-ray absorption fine structure

BackgroundThe gas ionization chamber is a kind of intensity monitoring detector widely used in Synchrotron Radiation Facility. Lytle detector is often used to measure the fluorescence signal from the element of interest in the fluorescent mode XAFS (X-ray absorption fine structure), it is one of the important fluorescence detectors for the X-ray absorption spectrum study and used in XAFS beamline station of Shanghai Synchrotron Radiation Facility (SSRF). However, this type detector is predominantly manufactured by foreign company (The EXAFS Company).PurposeThis study aims to develop a domestic fluorescent gas detector according to the operating conditions and technical requirements of fluorescent mode XAFS.MethodsFirstly, a filter and a slit assembly were designed and optimized with Geant4 toolkit. Subsequently, a multilayer grid ionization chamber for fluorescence detection was designed, and the supporting electronics circuit with both high voltage and amplification gain functions was designed. Secondly, all components were manufactured and assembled into a complete detector, and the digital noise, response time, response intensity, and linearity of self-developed detector were tested at BL11B beamline of SSRF. Finally, the actual measured performance of self-developed detector was tested and compared with Lytle detector at BL11B beamline.ResultsThe test results indicate that the digital noise level is approximately ~3.2×10-9 V, which is superior to the (9~10)×10-9 V observed in the Lytle detector. Additionally, the response time is less than 2.1 ms, significantly outperforming the Lytle detector's response time of approximately 150 ms. The linearity of the detector's response also exceeds 0.999 6.ConclusionsThe self-developed detector with shorter response times and better performance than Lytle detector has been achieved, and the localization replacement of the Lytle type detector is realized. Meanwhile, it has been used in the fluorescent mode XAFS of BL11B beamline at SSRF.

Publication Details

Journal
SHILAP Revista de lepidopterología
Published
2024-12-01
DOI
https://doi.org/10.11889/j.0253-3219.2024.hjs.47.120401
Primary Topic
Particle Detector Development and Performance
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Design and development of fluorescence gas detector for X-ray absorption fine structure

SHILAP Revista de lepidopterología
Particle Detector Development and Performance
article

Design and development of fluorescence gas detector for X-ray absorption fine structure

article en

Abstract

BackgroundThe gas ionization chamber is a kind of intensity monitoring detector widely used in Synchrotron Radiation Facility. Lytle detector is often used to measure the fluorescence signal from the element of interest in the fluorescent mode XAFS (X-ray absorption fine structure), it is one of the important fluorescence detectors for the X-ray absorption spectrum study and used in XAFS beamline station of Shanghai Synchrotron Radiation Facility (SSRF). However, this type detector is predominantly manufactured by foreign company (The EXAFS Company).PurposeThis study aims to develop a domestic fluorescent gas detector according to the operating conditions and technical requirements of fluorescent mode XAFS.MethodsFirstly, a filter and a slit assembly were designed and optimized with Geant4 toolkit. Subsequently, a multilayer grid ionization chamber for fluorescence detection was designed, and the supporting electronics circuit with both high voltage and amplification gain functions was designed. Secondly, all components were manufactured and assembled into a complete detector, and the digital noise, response time, response intensity, and linearity of self-developed detector were tested at BL11B beamline of SSRF. Finally, the actual measured performance of self-developed detector was tested and compared with Lytle detector at BL11B beamline.ResultsThe test results indicate that the digital noise level is approximately ~3.2×10-9 V, which is superior to the (9~10)×10-9 V observed in the Lytle detector. Additionally, the response time is less than 2.1 ms, significantly outperforming the Lytle detector's response time of approximately 150 ms. The linearity of the detector's response also exceeds 0.999 6.ConclusionsThe self-developed detector with shorter response times and better performance than Lytle detector has been achieved, and the localization replacement of the Lytle type detector is realized. Meanwhile, it has been used in the fluorescent mode XAFS of BL11B beamline at SSRF.

SHILAP Revista de lepidopterología
Openalex Percentile: Top 92%
Particle Detector Development and Performance
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.