Development of 2D/3D X-ray imaging system based on small size betatron

BackgroundCompared with commercial X-ray tubes, Betatron can emit MeV-level X-rays and its penetration capability is better than that of keV-level X-rays, which can be used for non-destructive testing (NDT) of large workpieces.PurposeThis study aims to design and build a 2D/3D X-ray imaging platform for NDT of large workpieces by using a compact Betatron as the X-ray source.MethodsFirstly, the hardware of the imaging platform was designed. It consisted of the compact Betatron with X-ray energy of 2.50/7.50 MeV, a high-energy X-ray line array detector with GGAG(Gd3Ga2Al3O12) scintillator and a two-axis mobile platform. Then, based on the principle and image correction algorithm of the 2D imaging system, the stripe noise characteristics in both the pixel direction and time direction were analyzed, and the blank pixel correction method was employed to correct the two-dimensional image. Its two-dimensional imaging performance test was conducted on a 6 cm square steel workpiece. Finally, three-dimensional image reconstruction of the workpiece was achieved by rotating the workpiece to obtain projection values at different angles, and the spatial resolution of 3D imaging was calculated using logistic function fitting method. Results of different tomographic reconstruction algorithms were compared and analyzed to obtain important 3D imaging system parameters.ResultsMeasurement results show that the thickness of the stainless-steel half-value layer of the system is 24.94 mm, the 2D imaging spatial resolution is 2.12 mm, and the tomographic reconstruction image spatial resolution is 1.00 mm.ConclusionsCompared with the keV-level X-ray imaging system, this system can complete the non-destructive testing of larger workpieces.

Institutions

Publication Details

Journal
SHILAP Revista de lepidopterología
Published
2024-12-01
DOI
https://doi.org/10.11889/j.0253-3219.2024.hjs.47.120202
Primary Topic
Advanced X-ray and CT Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development of 2D/3D X-ray imaging system based on small size betatron

SHILAP Revista de lepidopterología
Advanced X-ray and CT Imaging
article

Development of 2D/3D X-ray imaging system based on small size betatron

article en

Abstract

BackgroundCompared with commercial X-ray tubes, Betatron can emit MeV-level X-rays and its penetration capability is better than that of keV-level X-rays, which can be used for non-destructive testing (NDT) of large workpieces.PurposeThis study aims to design and build a 2D/3D X-ray imaging platform for NDT of large workpieces by using a compact Betatron as the X-ray source.MethodsFirstly, the hardware of the imaging platform was designed. It consisted of the compact Betatron with X-ray energy of 2.50/7.50 MeV, a high-energy X-ray line array detector with GGAG(Gd3Ga2Al3O12) scintillator and a two-axis mobile platform. Then, based on the principle and image correction algorithm of the 2D imaging system, the stripe noise characteristics in both the pixel direction and time direction were analyzed, and the blank pixel correction method was employed to correct the two-dimensional image. Its two-dimensional imaging performance test was conducted on a 6 cm square steel workpiece. Finally, three-dimensional image reconstruction of the workpiece was achieved by rotating the workpiece to obtain projection values at different angles, and the spatial resolution of 3D imaging was calculated using logistic function fitting method. Results of different tomographic reconstruction algorithms were compared and analyzed to obtain important 3D imaging system parameters.ResultsMeasurement results show that the thickness of the stainless-steel half-value layer of the system is 24.94 mm, the 2D imaging spatial resolution is 2.12 mm, and the tomographic reconstruction image spatial resolution is 1.00 mm.ConclusionsCompared with the keV-level X-ray imaging system, this system can complete the non-destructive testing of larger workpieces.

SHILAP Revista de lepidopterología
Lanzhou University (CN), Nanjing University of Aeronautics and Astronautics (CN)
Openalex Percentile: Top 73%
Advanced X-ray and CT Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.