Processing of real-time surface electromyography signals during knee movements of rehabilitation participants

<p>In this work, we present a knee rehabilitation system focusing on the processing of surface electromyography (sEMG) signals measured from the vastus lateralis (VL) and vastus medialis (VM) muscles of rehabilitation participants. A two-channel electromyography (EMG) device and the NI-myRIO embedded device are used to collect real-time sEMG signals in accordance with pre-designed rehabilitation programs. The novelty and contribution of this work is that we develop an sEMG processing function where real-time sEMG data are automatically processed and sEMG results of both VL and VM in terms of root mean square value (RMS), different RMS levels of VL and VM, and maximum RMS for each round of knee movements are provided. The results here indicate how well the rehabilitation users can move their knees during rehabilitation, referring to knee and muscle performances. Experimental results from healthy participants show that we can automatically and efficiently collect and monitor rehabilitation results, allowing rehabilitation participants to know how their knees performed during testing and medical experts to evaluate and design treatment.</p>

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2024-12-01
DOI
https://doi.org/10.11591/ijece.v14i6.pp3526-6537
Primary Topic
Muscle activation and electromyography studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Processing of real-time surface electromyography signals during knee movements of rehabilitation participants

Zenodo (CERN European Organization for Nuclear Research)
Muscle activation and electromyography studies
article

Processing of real-time surface electromyography signals during knee movements of rehabilitation participants

article en

Abstract

<p>In this work, we present a knee rehabilitation system focusing on the processing of surface electromyography (sEMG) signals measured from the vastus lateralis (VL) and vastus medialis (VM) muscles of rehabilitation participants. A two-channel electromyography (EMG) device and the NI-myRIO embedded device are used to collect real-time sEMG signals in accordance with pre-designed rehabilitation programs. The novelty and contribution of this work is that we develop an sEMG processing function where real-time sEMG data are automatically processed and sEMG results of both VL and VM in terms of root mean square value (RMS), different RMS levels of VL and VM, and maximum RMS for each round of knee movements are provided. The results here indicate how well the rehabilitation users can move their knees during rehabilitation, referring to knee and muscle performances. Experimental results from healthy participants show that we can automatically and efficiently collect and monitor rehabilitation results, allowing rehabilitation participants to know how their knees performed during testing and medical experts to evaluate and design treatment.</p>

Zenodo (CERN European Organization for Nuclear Research)
Good health and well-being
Openalex Percentile: Top 73%
Muscle activation and electromyography studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.