An Optimized Scheme for Active Distribution Network Current Speed Protection Setting Considering Tie Switch Operation

Active distribution grid with tie switches has a complex grid structure and undergo frequent changes in operation mode, which greatly affects the correct operation of traditional current protection that relies on static grid topology and fixed operation mode. A setting optimization scheme for instantaneous overcurrent protection is proposed, which monitors the switch status information in real-time by the terminal unit, uploads the topology correlation matrix to the master station, and combines the output characteristics of the inverter-type distributed power supply to adaptively adjust the protection settings. The scheme can effectively enhance the adaptability of the protection to the grid topology and the output fluctuation of the inverter-type power supply with low communication pressure. Simulation results show that it can effectively increase the instantaneous overcurrent protection range, reduce the impact of DG output and better adapt to grid topology changes.

Publication Details

Journal
SHILAP Revista de lepidopterología
Published
2024-10-01
DOI
https://doi.org/10.11930/j.issn.1004-9649.202402026
Primary Topic
Power Systems Fault Detection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

An Optimized Scheme for Active Distribution Network Current Speed Protection Setting Considering Tie Switch Operation

SHILAP Revista de lepidopterología
Power Systems Fault Detection
article

An Optimized Scheme for Active Distribution Network Current Speed Protection Setting Considering Tie Switch Operation

article en

Abstract

Active distribution grid with tie switches has a complex grid structure and undergo frequent changes in operation mode, which greatly affects the correct operation of traditional current protection that relies on static grid topology and fixed operation mode. A setting optimization scheme for instantaneous overcurrent protection is proposed, which monitors the switch status information in real-time by the terminal unit, uploads the topology correlation matrix to the master station, and combines the output characteristics of the inverter-type distributed power supply to adaptively adjust the protection settings. The scheme can effectively enhance the adaptability of the protection to the grid topology and the output fluctuation of the inverter-type power supply with low communication pressure. Simulation results show that it can effectively increase the instantaneous overcurrent protection range, reduce the impact of DG output and better adapt to grid topology changes.

SHILAP Revista de lepidopterología
Affordable and clean energy
Openalex Percentile: Top 61%
Power Systems Fault Detection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.