Design and test of multi-variable estimation-based calibration for vector modulator

BackgroundThe RF output amplitude of the Low Level Radio Frequency (LLRF) system in Shanghai Soft X-ray Free-electron Laser (SXFEL) exhibits oscillations during the search for the maximum accelerating phase, compromisingthe stability of the entire device.PurposeThis study aims to develope a multi-variable estimation-based calibration technology for the Vector Modulator (VM) to stabilize the RF output amplitude and reduce the crosstalk between the amplitude and phase loops in closed-loop control.MethodsA non-ideal model of the VM was analyzed and established to address output amplitude stabilization in the LLRF system's microwave power source. The parameters of this model were estimated using real input and output data from the VM. A calibration algorithm was then designed and implemented to mitigate the adverse effects caused by non-ideal factors.ResultsExperimental results demonstrate that the proposed method reduces the impact of phase setpoint changes on the VM's output amplitude from 4.0% Root Mean Square (RMS) to 0.19% RMS after calibration. Furthermore, the error between the phase setpoint and measured phase was reduced to within 0.18° RMS.ConclusionsThis proposed method improvesisolation between amplitude and phase, effectively eliminating phase differences between the output and sampled waveforms.

Institutions

Publication Details

Journal
SHILAP Revista de lepidopterología
Published
2024-11-01
DOI
https://doi.org/10.11889/j.0253-3219.2024.hjs.47.110202
Primary Topic
Particle Accelerators and Free-Electron Lasers
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Design and test of multi-variable estimation-based calibration for vector modulator

SHILAP Revista de lepidopterología
Particle Accelerators and Free-Electron Lasers
article

Design and test of multi-variable estimation-based calibration for vector modulator

article en

Abstract

BackgroundThe RF output amplitude of the Low Level Radio Frequency (LLRF) system in Shanghai Soft X-ray Free-electron Laser (SXFEL) exhibits oscillations during the search for the maximum accelerating phase, compromisingthe stability of the entire device.PurposeThis study aims to develope a multi-variable estimation-based calibration technology for the Vector Modulator (VM) to stabilize the RF output amplitude and reduce the crosstalk between the amplitude and phase loops in closed-loop control.MethodsA non-ideal model of the VM was analyzed and established to address output amplitude stabilization in the LLRF system's microwave power source. The parameters of this model were estimated using real input and output data from the VM. A calibration algorithm was then designed and implemented to mitigate the adverse effects caused by non-ideal factors.ResultsExperimental results demonstrate that the proposed method reduces the impact of phase setpoint changes on the VM's output amplitude from 4.0% Root Mean Square (RMS) to 0.19% RMS after calibration. Furthermore, the error between the phase setpoint and measured phase was reduced to within 0.18° RMS.ConclusionsThis proposed method improvesisolation between amplitude and phase, effectively eliminating phase differences between the output and sampled waveforms.

SHILAP Revista de lepidopterología
Chinese Academy of Sciences (CN), Shanghai Advanced Research Institute (CN)
Affordable and clean energy
Openalex Percentile: Top 71%
Particle Accelerators and Free-Electron Lasers
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.