Methodological validation study of nrCE-SDS for monoclonal antibodies

Objective To perform methodological validation of non-reduced capillary electrophoresis-sodium dodecyl sulfate (nrCE-SDS) for monoclonal antibodies, providing a reference for the methodological validation of corresponding quality control methods in the industry. Methods Samples were analyzed according to the general chapter <3127> determination method for monoclonal antibody molecular size variants in the Pharmacopoeia of the People's Republic of China (2020 edition). Two laboratory technicians performed experiments over three days, using the same detection method daily to analyze the test samples, alongside comprehensive methodological validation. Results The method demonstrated good specificity, with the accuracy of the main peaks of all analytical samples reaching 98% to 102%, and the accuracy of total fragments and specific impurities reaching 70% to 130%. The relative standard deviation (RSD) for repeatability and intermediate precision was ≤15%. The ranges for the main peak, total fragment, and specific impurity were ≥89.9%, 0.66% to 10.10%, and 0.36% to 4.80%, respectively.The limit of quantification of the method was 0.33%. Conclusion Full validation demonstrates good accuracy, precision, linearity, range, limit of quantification, and specificity of the method, providing a reference for the scientific and rational design of corresponding methodological validations.

Publication Details

Journal
SHILAP Revista de lepidopterología
Published
2024-12-01
DOI
https://doi.org/10.12287/j.issn.2096-8965.20240410
Primary Topic
Microfluidic and Capillary Electrophoresis Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Methodological validation study of nrCE-SDS for monoclonal antibodies

SHILAP Revista de lepidopterología
Microfluidic and Capillary Electrophoresis Applications
article

Methodological validation study of nrCE-SDS for monoclonal antibodies

article en

Abstract

Objective To perform methodological validation of non-reduced capillary electrophoresis-sodium dodecyl sulfate (nrCE-SDS) for monoclonal antibodies, providing a reference for the methodological validation of corresponding quality control methods in the industry. Methods Samples were analyzed according to the general chapter <3127> determination method for monoclonal antibody molecular size variants in the Pharmacopoeia of the People's Republic of China (2020 edition). Two laboratory technicians performed experiments over three days, using the same detection method daily to analyze the test samples, alongside comprehensive methodological validation. Results The method demonstrated good specificity, with the accuracy of the main peaks of all analytical samples reaching 98% to 102%, and the accuracy of total fragments and specific impurities reaching 70% to 130%. The relative standard deviation (RSD) for repeatability and intermediate precision was ≤15%. The ranges for the main peak, total fragment, and specific impurity were ≥89.9%, 0.66% to 10.10%, and 0.36% to 4.80%, respectively.The limit of quantification of the method was 0.33%. Conclusion Full validation demonstrates good accuracy, precision, linearity, range, limit of quantification, and specificity of the method, providing a reference for the scientific and rational design of corresponding methodological validations.

SHILAP Revista de lepidopterología
Industry, innovation and infrastructure
Openalex Percentile: Top 73%
Microfluidic and Capillary Electrophoresis Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Methodological validation study of nrCE-SDS for monoclonal antibodies · SHILAP Revista de lepidopterología (2024) | TGRS Research Map | TGRS