AC contactor fault recognition based on ERF and BO-SVC

In response to the challenges posed by imbalanced samples leading to low recognition accuracy and high feature redundancy in AC contactor, a novel composite recognition methodology which is leverages embedded random forest (ERF) and Bayesian optimization-support vector classification (BO-SVC) is introduced. Firstly, the extraction of contactor state features from the full life testing platform designed for contactor is initiated. To counteract the low recognition accuracy caused by the imbalance among different state samples, a sample balancing strategy based on the weighted method is proposed. Subsequently, the ERF is employed to perform feature selection and reduction on the balanced samples. This process leads to the extraction of optimal features that represent the dynamic patterns of AC contactor state changes. Following the feature extraction step, the selected optimal features are fed into BO-SVC recognition model. A comprehensive evaluation of BO-SVC's fault recognition capabilities is undertaken, compared with two other representative models, the performance of each model is evaluated based on three indicators: accuracy, recall, and F1-score. The results of the proposed method reaches 95.22%, 98.91%, and 97.01%, respectively, all of which are higher than the comparison models. Using F1-score as an indicator, the performance of each model is tested on four sets of samples, and the results showed that the F1-score of the proposed method is on average 0.56% and 27.28% higher than the compared models, respectively. The research in the article effectively solves the problems of redundant characteristics and low fault recognition accuracy of AC contactors.

Institutions

Publication Details

Journal
SHILAP Revista de lepidopterología
Published
2024-11-01
DOI
https://doi.org/10.12158/j.2096-3203.2024.06.017
Primary Topic
Electrical Contact Performance and Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

AC contactor fault recognition based on ERF and BO-SVC

SHILAP Revista de lepidopterología
Electrical Contact Performance and Analysis
article

AC contactor fault recognition based on ERF and BO-SVC

article en

Abstract

In response to the challenges posed by imbalanced samples leading to low recognition accuracy and high feature redundancy in AC contactor, a novel composite recognition methodology which is leverages embedded random forest (ERF) and Bayesian optimization-support vector classification (BO-SVC) is introduced. Firstly, the extraction of contactor state features from the full life testing platform designed for contactor is initiated. To counteract the low recognition accuracy caused by the imbalance among different state samples, a sample balancing strategy based on the weighted method is proposed. Subsequently, the ERF is employed to perform feature selection and reduction on the balanced samples. This process leads to the extraction of optimal features that represent the dynamic patterns of AC contactor state changes. Following the feature extraction step, the selected optimal features are fed into BO-SVC recognition model. A comprehensive evaluation of BO-SVC's fault recognition capabilities is undertaken, compared with two other representative models, the performance of each model is evaluated based on three indicators: accuracy, recall, and F1-score. The results of the proposed method reaches 95.22%, 98.91%, and 97.01%, respectively, all of which are higher than the comparison models. Using F1-score as an indicator, the performance of each model is tested on four sets of samples, and the results showed that the F1-score of the proposed method is on average 0.56% and 27.28% higher than the compared models, respectively. The research in the article effectively solves the problems of redundant characteristics and low fault recognition accuracy of AC contactors.

SHILAP Revista de lepidopterología
Shenyang University (CN)
Responsible consumption and production
Openalex Percentile: Top 69%
Electrical Contact Performance and Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.