Research on synchronous radiation scanning transmission X-ray microscopy system closed-loop control method

BackgroundThe Scanning Transmission X-ray Microscopy (STXM) endstation, located at the Shanghai Synchrotron Radiation Facility (SSRF), stands as China's sole STXM device. It boasts the capability for high spatial resolution imaging down to a 15 nm scale. Utilizing the scanning coherent diffraction imaging method (i.e. ptychography), this station achieves an optimal resolution of 7.32 nm, necessitating utmost system stability. However, the STXM system operates within a complex environment where the impact of external vibrations on imaging quality is increasingly problematic.PurposeThis study aims to develop a closed loop control method for the vibration of STXM system to improve imaging quality.MethodsFirst of all, system vibration between the Fresnel zone plate (FZP) and the sample was analyzed in detail, so did the vibration suppression methods. Then, a software-driven closed-loop control system was developed on Field Programmable Gate Array (FPGA) platform by leveraging these insights, and a Fast Fourier Transform (FFT) based approach was implemented to process precise (picometer-scale) and rapid (1 kHz) positional data captured by a laser interferometer. Finally, the internal sensor of motor controller was replaced by laser interferometer to realize the closed-loop control to suppress vertical vibration, and vibration data were applied to a piezo motor for effectively replacing its internal sensors to suppress system vibrations.ResultsThe optimal performance achieved by the closed-loop control scheme shows that the root mean square (RMS) value of the vibration is reduced to 4.833 nm, which is around one third of the value before.ConclusionsThe successful implementation of this closed-loop control scheme has furnished robust technical foundations for further enhancements in the imaging resolution of the STXM system.

Publication Details

Journal
SHILAP Revista de lepidopterología
Published
2024-09-01
DOI
https://doi.org/10.11889/j.0253-3219.2024.hjs.47.090101
Citations
1
Primary Topic
Advanced X-ray Imaging Techniques
Type
article
Field-Weighted Citation Impact
0.61
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Research on synchronous radiation scanning transmission X-ray microscopy system closed-loop control method

1 citations
SHILAP Revista de lepidopterología
Advanced X-ray Imaging Techniques
0.61
article

Research on synchronous radiation scanning transmission X-ray microscopy system closed-loop control method

article en
1 citations

Abstract

BackgroundThe Scanning Transmission X-ray Microscopy (STXM) endstation, located at the Shanghai Synchrotron Radiation Facility (SSRF), stands as China's sole STXM device. It boasts the capability for high spatial resolution imaging down to a 15 nm scale. Utilizing the scanning coherent diffraction imaging method (i.e. ptychography), this station achieves an optimal resolution of 7.32 nm, necessitating utmost system stability. However, the STXM system operates within a complex environment where the impact of external vibrations on imaging quality is increasingly problematic.PurposeThis study aims to develop a closed loop control method for the vibration of STXM system to improve imaging quality.MethodsFirst of all, system vibration between the Fresnel zone plate (FZP) and the sample was analyzed in detail, so did the vibration suppression methods. Then, a software-driven closed-loop control system was developed on Field Programmable Gate Array (FPGA) platform by leveraging these insights, and a Fast Fourier Transform (FFT) based approach was implemented to process precise (picometer-scale) and rapid (1 kHz) positional data captured by a laser interferometer. Finally, the internal sensor of motor controller was replaced by laser interferometer to realize the closed-loop control to suppress vertical vibration, and vibration data were applied to a piezo motor for effectively replacing its internal sensors to suppress system vibrations.ResultsThe optimal performance achieved by the closed-loop control scheme shows that the root mean square (RMS) value of the vibration is reduced to 4.833 nm, which is around one third of the value before.ConclusionsThe successful implementation of this closed-loop control scheme has furnished robust technical foundations for further enhancements in the imaging resolution of the STXM system.

SHILAP Revista de lepidopterología
Openalex Percentile: Top 27%
Advanced X-ray Imaging Techniques
0.61
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Research on synchronous radiation scanning transmission X-ray microscopy system closed-loop control method · SHILAP Revista de lepidopterología (2024) | TGRS Research Map | TGRS