Towards Transabdominal Fetal Pulse Oximetry: Computational Modeling and Algorithm Development

Non-invasive fetal oxygen monitoring is critical for assessing fetal well-being and preventing adverse outcomes caused by fetal hypoxia. Current clinical standards, such as cardiotocography (CTG), primarily rely on measurements of fetal heart rate and maternal contractions, both of which are indirect indicators of actual fetal oxygenation status. As a result, CTG often produces false-positive results, leading to unnecessary medical interventions. Transabdominal fetal pulse oximetry, in contrast, offers the potential for direct, continuous, and non-invasive estimation of fetal oxygen saturation (SpO2). However, significant physiological and technical challenges—including strong maternal tissue interference, complex multi-layer photon propagation, and motion artifacts—have limited its clinical adoption. This dissertation addresses these challenges and advances transabdominal fetal pulse oximetry toward clinical feasibility through computational modeling and algorithmic innovations. First, a novel self-calibrated pulse oximetry algorithm was developed to overcome a fundamental limitation: conventional pulse oximeters re quire empirical calibration on healthy subjects, resulting in inaccuracies when applied to low-oxygen saturation conditions like those in fetal circulation. The proposed algorithm significantly improves accuracy in the low SpO2 range relevant for fetal applications. Next, the self-calibrated algorithm was extended by incorporating multi layer photon transport modeling, which allows accurate fetal SpO<sub>2</sub> estimation despite significant maternal tissue interference. To enhance real-world applicability, extensive sensitivity analyses based on MRI-derived anatomical models were conducted to optimize device configuration and evaluate the effects of fetal positioning. Finally, a deep learning framework utilizing long short-term memory networks was developed to robustly remove motion artifacts from pulsatile optical signals, further improving measurement reliability in clinical environments. Together, these advancements provide a solid foundation for accurate, continuous, and non-invasive fetal SpO<sub>2</sub> monitoring, creating pathways toward safer and more effective fetal health monitoring in clinical practice. Additionally, these methodologies offer valuable tools applicable to a wide range of other optical physiological monitoring applications.

Institutions

Publication Details

Journal
KiltHub Repository
Published
2025-01-01
DOI
https://doi.org/10.1184/r1/29089811
Primary Topic
Optical Imaging and Spectroscopy Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Towards Transabdominal Fetal Pulse Oximetry: Computational Modeling and Algorithm Development

KiltHub Repository
Optical Imaging and Spectroscopy Techniques
article

Towards Transabdominal Fetal Pulse Oximetry: Computational Modeling and Algorithm Development

article en

Abstract

Non-invasive fetal oxygen monitoring is critical for assessing fetal well-being and preventing adverse outcomes caused by fetal hypoxia. Current clinical standards, such as cardiotocography (CTG), primarily rely on measurements of fetal heart rate and maternal contractions, both of which are indirect indicators of actual fetal oxygenation status. As a result, CTG often produces false-positive results, leading to unnecessary medical interventions. Transabdominal fetal pulse oximetry, in contrast, offers the potential for direct, continuous, and non-invasive estimation of fetal oxygen saturation (SpO2). However, significant physiological and technical challenges—including strong maternal tissue interference, complex multi-layer photon propagation, and motion artifacts—have limited its clinical adoption. This dissertation addresses these challenges and advances transabdominal fetal pulse oximetry toward clinical feasibility through computational modeling and algorithmic innovations. First, a novel self-calibrated pulse oximetry algorithm was developed to overcome a fundamental limitation: conventional pulse oximeters re quire empirical calibration on healthy subjects, resulting in inaccuracies when applied to low-oxygen saturation conditions like those in fetal circulation. The proposed algorithm significantly improves accuracy in the low SpO2 range relevant for fetal applications. Next, the self-calibrated algorithm was extended by incorporating multi layer photon transport modeling, which allows accurate fetal SpO<sub>2</sub> estimation despite significant maternal tissue interference. To enhance real-world applicability, extensive sensitivity analyses based on MRI-derived anatomical models were conducted to optimize device configuration and evaluate the effects of fetal positioning. Finally, a deep learning framework utilizing long short-term memory networks was developed to robustly remove motion artifacts from pulsatile optical signals, further improving measurement reliability in clinical environments. Together, these advancements provide a solid foundation for accurate, continuous, and non-invasive fetal SpO<sub>2</sub> monitoring, creating pathways toward safer and more effective fetal health monitoring in clinical practice. Additionally, these methodologies offer valuable tools applicable to a wide range of other optical physiological monitoring applications.

KiltHub Repository
Carnegie Mellon University (US)
Openalex Percentile: Top 43%
Optical Imaging and Spectroscopy Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.