Application value of single energy metal artifact reduction in the follow-up CT angiography after endovascular repair of abdominal aortic aneurysm combined with coil embolization

ObjectiveTo explore the application value of single energy metal artifact reduction technology (SEMAR) in the CTA follow-up of complex abdominal aortic aneurysm endovascular repair (EVAR) combined with coil embolization using 320-slice CT spiral scanning mode. MethodsA retrospective analysis was conducted on the images of 14 patients with abdominal aortic aneurysm and 2 patients with internal iliac artery aneurysm who underwent abdominal CTA reexamination 30 days after EVAR combined with coil embolization at Zhongshan Hospital, Fudan University from August 2023 to February 2024. The original data were reconstructed using a hybrid iterative reconstruction algorithm (non-SEMAR group) and a combined reconstruction and SEMAR algorithm (SEMAR group), and the artifact index (AI), contrast-to-noise ratio (CNR), and subjective scores between the two groups were compared. ResultsThe AI values of up, down, left, right around the spring coil and adjacent aortic cavity in the SEMAR group were lower than those in the non-SEMAR group (38.16±19.20 vs 89.29±30.93, 30.75±16.28 vs 82.62±28.01, 33.61±16.18 vs 74.90±26.28, 44.99±15.91 vs 87.72±33.70, and 24.49±12.58 vs 47.29±13.55; P<0.001), and the CNRs in the SEMAR group were higher than those in the non-SEMAR group (2.47±2.15 vs 1.01±0.74, 2.32±2.01 vs 0.72±0.50, 4.93±4.15 vs 1.38±0.79, 4.10±4.14 vs 1.56±1.18, and 19.91±11.01 vs 11.01±7.77; P<0.05). Compared with the non-SEMAR group, the subjective scores of image in the SEMAR group were higher (P<0.001). ConclusionsSEMAR technology can significantly reduce the artifact of spring coil, improve the clarity of tumors, visceral arteries, stents, and internal leaks images, and has important clinical significance for follow-up after EVAR surgery.

Institutions

Publication Details

Journal
SHILAP Revista de lepidopterología
Published
2024-12-01
DOI
https://doi.org/10.12025/j.issn.1008-6358.2024.20240920
Primary Topic
Advanced X-ray and CT Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Application value of single energy metal artifact reduction in the follow-up CT angiography after endovascular repair of abdominal aortic aneurysm combined with coil embolization

SHILAP Revista de lepidopterología
Advanced X-ray and CT Imaging
article

Application value of single energy metal artifact reduction in the follow-up CT angiography after endovascular repair of abdominal aortic aneurysm combined with coil embolization

article en

Abstract

ObjectiveTo explore the application value of single energy metal artifact reduction technology (SEMAR) in the CTA follow-up of complex abdominal aortic aneurysm endovascular repair (EVAR) combined with coil embolization using 320-slice CT spiral scanning mode. MethodsA retrospective analysis was conducted on the images of 14 patients with abdominal aortic aneurysm and 2 patients with internal iliac artery aneurysm who underwent abdominal CTA reexamination 30 days after EVAR combined with coil embolization at Zhongshan Hospital, Fudan University from August 2023 to February 2024. The original data were reconstructed using a hybrid iterative reconstruction algorithm (non-SEMAR group) and a combined reconstruction and SEMAR algorithm (SEMAR group), and the artifact index (AI), contrast-to-noise ratio (CNR), and subjective scores between the two groups were compared. ResultsThe AI values of up, down, left, right around the spring coil and adjacent aortic cavity in the SEMAR group were lower than those in the non-SEMAR group (38.16±19.20 vs 89.29±30.93, 30.75±16.28 vs 82.62±28.01, 33.61±16.18 vs 74.90±26.28, 44.99±15.91 vs 87.72±33.70, and 24.49±12.58 vs 47.29±13.55; P<0.001), and the CNRs in the SEMAR group were higher than those in the non-SEMAR group (2.47±2.15 vs 1.01±0.74, 2.32±2.01 vs 0.72±0.50, 4.93±4.15 vs 1.38±0.79, 4.10±4.14 vs 1.56±1.18, and 19.91±11.01 vs 11.01±7.77; P<0.05). Compared with the non-SEMAR group, the subjective scores of image in the SEMAR group were higher (P<0.001). ConclusionsSEMAR technology can significantly reduce the artifact of spring coil, improve the clarity of tumors, visceral arteries, stents, and internal leaks images, and has important clinical significance for follow-up after EVAR surgery.

SHILAP Revista de lepidopterología
Sun Yat-sen University (CN), Fudan University (CN), Zhongshan Hospital (CN), The First Affiliated Hospital, Sun Yat-sen University (CN)
Affordable and clean energy
Openalex Percentile: Top 73%
Advanced X-ray and CT Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Application value of single energy metal artifact reduction in the follow-up CT angiography after endovascular repair of abdominal aortic aneurysm combined with coil embolization · SHILAP Revista de lepidopterología (2024) | TGRS Research Map | TGRS