Design and Characterization of a Soft Rehabilitation Glove Structure to Optimize the Interaction Forces

The increasing use of rehabilitation robots has brought to the forefront the importance of safe and effective human-robot interaction. Soft rehabilitation gloves, due to their lightweight nature and better conformity to the human hand, have gained significant attention. However, optimizing the design of soft gloves to minimize patient discomfort remains a significant challenge. This study presents a systematic approach to optimize the design of a cable-driven soft rehabilitation glove to minimize the forces exerted on the patient's finger joints. In this process, a detailed kinematic analysis of a cable-driven glove finger is first performed, enabling the creation of a finger model to optimize the forces applied to its joints. By considering a desired configuration, using the gradient descent method to determine the cable tension, and evaluating various cable attachment points on the soft glove for internal force optimization, an optimized glove design is proposed for minimizing the force on the patient's joints. Results demonstrate a 43.65% reduction in internal forces exerted on the patient's joints when cables are attached at the optimized points compared to the initial reference design. This research contributes to developing more comfortable and practical soft rehabilitation gloves for patients.

Institutions

Publication Details

Published
2024-12-17
DOI
https://doi.org/10.1109/icrom64545.2024.10903562
Primary Topic
Prosthetics and Rehabilitation Robotics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Design and Characterization of a Soft Rehabilitation Glove Structure to Optimize the Interaction Forces

Prosthetics and Rehabilitation Robotics
article

Design and Characterization of a Soft Rehabilitation Glove Structure to Optimize the Interaction Forces

article en

Abstract

The increasing use of rehabilitation robots has brought to the forefront the importance of safe and effective human-robot interaction. Soft rehabilitation gloves, due to their lightweight nature and better conformity to the human hand, have gained significant attention. However, optimizing the design of soft gloves to minimize patient discomfort remains a significant challenge. This study presents a systematic approach to optimize the design of a cable-driven soft rehabilitation glove to minimize the forces exerted on the patient's finger joints. In this process, a detailed kinematic analysis of a cable-driven glove finger is first performed, enabling the creation of a finger model to optimize the forces applied to its joints. By considering a desired configuration, using the gradient descent method to determine the cable tension, and evaluating various cable attachment points on the soft glove for internal force optimization, an optimized glove design is proposed for minimizing the force on the patient's joints. Results demonstrate a 43.65% reduction in internal forces exerted on the patient's joints when cables are attached at the optimized points compared to the initial reference design. This research contributes to developing more comfortable and practical soft rehabilitation gloves for patients.

Amirkabir University of Technology (IR)
Openalex Percentile: Top 73%
Prosthetics and Rehabilitation Robotics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.