Position closed loop control of stepper motors based on arctangent function

\nThe high-precision position closed-loop control of stepper motors usually use field-oriented control. This method requires high-precision models of motors, however stepper motors are complex nonlinear systems, and high-precision models are difficult to obtain. In order to solve this problem, a pulse frequency modulation controller based on arc tangent function is proposed in this paper. This algorithm does not need accurate mathematical model, and its turning parameters have clear physical significance, which can be calculated according to the control requirements. The experimental results show that when tracking the sinusoidal signal θref=450sin(0.628t), the tracking errors (peak-peak value) of the arctangent control algorithm is reduced by nearly 42% compared with the PI control algorithm, which provides a new idea for the position closed-loop control of stepper motors.\n

Publication Details

Journal
Springer Link (Chiba Institute of Technology)
Published
2024-12-06
DOI
https://doi.org/10.1051/jnwpu/20244250912/pdf
Primary Topic
Sensorless Control of Electric Motors
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Position closed loop control of stepper motors based on arctangent function

Springer Link (Chiba Institute of Technology)
Sensorless Control of Electric Motors
article

Position closed loop control of stepper motors based on arctangent function

article en

Abstract

\nThe high-precision position closed-loop control of stepper motors usually use field-oriented control. This method requires high-precision models of motors, however stepper motors are complex nonlinear systems, and high-precision models are difficult to obtain. In order to solve this problem, a pulse frequency modulation controller based on arc tangent function is proposed in this paper. This algorithm does not need accurate mathematical model, and its turning parameters have clear physical significance, which can be calculated according to the control requirements. The experimental results show that when tracking the sinusoidal signal θref=450sin(0.628t), the tracking errors (peak-peak value) of the arctangent control algorithm is reduced by nearly 42% compared with the PI control algorithm, which provides a new idea for the position closed-loop control of stepper motors.\n

Springer Link (Chiba Institute of Technology)
Affordable and clean energy
Openalex Percentile: Top 71%
Sensorless Control of Electric Motors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.