The Design of a Leakage Detection System for Industrial and Mining Wastewater Pipelines Based on Multi-Electrode Method Integration
To address the issue of industrial and mining wastewater leakage, this paper proposes a novel detection method for underground non-pressurized pipelines based on the combination of multiple electrical methods. The method integrates the high-density electrical method and the natural potential method, utilizing the naturally powered natural potential method for real-time monitoring. When a suspected leakage is de- tected, the high-density electrical method is used for precise localization and analysis of the leakage, enabling effective monitoring of industrial and mining wastewater leakage. A corresponding portable detection system has been designed, and both the detection method and the system have been validated through experiments.
Publication Details
- Journal
- Springer Link (Chiba Institute of Technology)
- Published
- 2025-05-22
- DOI
- https://doi.org/10.1051/e3sconf/202563001001/pdf
- Primary Topic
- Water Systems and Optimization
- Type
- article
- Field-Weighted Citation Impact
- 0.00