The alignment of the accelerator modules of the Cool Copper Collider C

\nFor C3, some 2000 accelerator modules must be 5D positioned, within 10 µm transversal, on a 2.3 km long straight line, for both linacs. In the Rasnik alignment system, light from a point-like monochromatic source falls on a zone lens, forming a Fraunhofer diffraction pattern on an image pixel sensor. The alignment of three objects can be obtained by analyzing the position of the diffraction pattern on the sensor. The alignment of a large number of objects can be realized by fixing a stick on each object, carrying all three Rasnik components. With this leap frog geometry, all sticks are mutually coupled, forming a multipoint alignment system.\nThe system should operate in ambient air, in vacuum, and in liquid nitrogen. Due to the heat dissipation of these components, bubbles are formed, causing an error in the measured alignment when crossing the optical path. Various methods of beam shielding are presented. With the Quarter Cryo Module (QCM), essential studies will be carried out, enabling the realization of C3. The QCM will be equipped with four Rasnik chains, measuring alignment parameters with redundancy. In addition, the bubble-induced vibrations of the accelerator components can be registered accurately.\n

Publication Details

Journal
Springer Link (Chiba Institute of Technology)
Published
2024-12-18
DOI
https://doi.org/10.1051/epjconf/202431502018/pdf
Primary Topic
Particle Accelerators and Free-Electron Lasers
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The alignment of the accelerator modules of the Cool Copper Collider C

Springer Link (Chiba Institute of Technology)
Particle Accelerators and Free-Electron Lasers
article

The alignment of the accelerator modules of the Cool Copper Collider C

article en

Abstract

\nFor C3, some 2000 accelerator modules must be 5D positioned, within 10 µm transversal, on a 2.3 km long straight line, for both linacs. In the Rasnik alignment system, light from a point-like monochromatic source falls on a zone lens, forming a Fraunhofer diffraction pattern on an image pixel sensor. The alignment of three objects can be obtained by analyzing the position of the diffraction pattern on the sensor. The alignment of a large number of objects can be realized by fixing a stick on each object, carrying all three Rasnik components. With this leap frog geometry, all sticks are mutually coupled, forming a multipoint alignment system.\nThe system should operate in ambient air, in vacuum, and in liquid nitrogen. Due to the heat dissipation of these components, bubbles are formed, causing an error in the measured alignment when crossing the optical path. Various methods of beam shielding are presented. With the Quarter Cryo Module (QCM), essential studies will be carried out, enabling the realization of C3. The QCM will be equipped with four Rasnik chains, measuring alignment parameters with redundancy. In addition, the bubble-induced vibrations of the accelerator components can be registered accurately.\n

Springer Link (Chiba Institute of Technology)
Openalex Percentile: Top 71%
Particle Accelerators and Free-Electron Lasers
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.