Possibilities of organizing microclimate systems on the basis of ultrasonic mist generator

The increase in average annual and summer temperatures in cities adversely affects the health of residents. To address the effects of climate change on urban populations, outdoor microclimate systems that spray liquid droplets are utilized. However, these systems have significant drawbacks, including high water usage and limited efficiency in reducing temperatures. In areas facing water scarcity, such as many Asian countries, microclimate systems that utilise ultrasonic mist generators appear to be a more viable option. This article presents a study examining the operation of a physical model of a climate system incorporating ultrasonic mist generators. Experimental data indicate that the cooling effect is evident within the first 2-3 minutes of system operation, with a temperature decrease rate of 0.7 oC/min observed. A mathematical model has been derived that describes the process of temperature reduction in the unit operation zone. The model is based on a hyperbolic function.

Publication Details

Journal
Springer Link (Chiba Institute of Technology)
Published
2024-08-30
DOI
https://doi.org/10.1051/e3sconf/202456303066/pdf
Primary Topic
Solar-Powered Water Purification Methods
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Possibilities of organizing microclimate systems on the basis of ultrasonic mist generator

Springer Link (Chiba Institute of Technology)
Solar-Powered Water Purification Methods
article

Possibilities of organizing microclimate systems on the basis of ultrasonic mist generator

article en

Abstract

The increase in average annual and summer temperatures in cities adversely affects the health of residents. To address the effects of climate change on urban populations, outdoor microclimate systems that spray liquid droplets are utilized. However, these systems have significant drawbacks, including high water usage and limited efficiency in reducing temperatures. In areas facing water scarcity, such as many Asian countries, microclimate systems that utilise ultrasonic mist generators appear to be a more viable option. This article presents a study examining the operation of a physical model of a climate system incorporating ultrasonic mist generators. Experimental data indicate that the cooling effect is evident within the first 2-3 minutes of system operation, with a temperature decrease rate of 0.7 oC/min observed. A mathematical model has been derived that describes the process of temperature reduction in the unit operation zone. The model is based on a hyperbolic function.

Springer Link (Chiba Institute of Technology)
Climate action
Openalex Percentile: Top 81%
Solar-Powered Water Purification Methods
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Possibilities of organizing microclimate systems on the basis of ultrasonic mist generator · Springer Link (Chiba Institute of Technology) (2024) | TGRS Research Map | TGRS