Non-destructive Thermal Monitoring of Temperature and Flow Rate of the Heat Carrier in a Heating Device

Conducting various calculations for the heating system of a building under operational conditions is impossible without knowledge of the temperature and flow rate of the heat carrier at specific points. Contact measurement means are not always applicable, especially for small-diameter pipelines. Measurement techniques based on the theory of non-destructive thermal inspection allow for remote and timely acquisition of all necessary information. The object of the study is the floor node of the building's heating system. The subject of the study is the temperature and flow rate of the heat carrier passing through the heating device. The research aim is to determine the temperature and flow rate of the heat carrier passing through the heating device under operational conditions. The research method involves the theory of non-destructive thermal inspection, as well as heat balance and heat transfer equations for a vertical flat wall. Research findings reveal that during thermovisual inspection, the temperature of the heat carrier in the supply and return pipelines of the floor node respectively amounted to 51.6 ℃ and 49.6 ℃. The flow rate of the heat carrier through the heating device model MS-140M2-500, with a heat transfer coefficient of 8.5 W/(m²⋅K), was determined to be 195.0 kg/h. Recommendations include utilizing a thermal imager with an absolute measurement error not exceeding ±0.15 ℃ for determining the flow rate of the heat carrier through the heating device. The influence of measurement error of indoor air temperature on the accuracy of determining the heat carrier flow rate is insignificant (not exceeding ±2%). The relative error in determining the heat transfer coefficient of the heating device does not exceed ±1%.

Publication Details

Journal
Springer Link (Chiba Institute of Technology)
Published
2024-10-21
DOI
https://doi.org/10.1051/e3sconf/202458101049/pdf
Primary Topic
Thermography and Photoacoustic Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Non-destructive Thermal Monitoring of Temperature and Flow Rate of the Heat Carrier in a Heating Device

Springer Link (Chiba Institute of Technology)
Thermography and Photoacoustic Techniques
article

Non-destructive Thermal Monitoring of Temperature and Flow Rate of the Heat Carrier in a Heating Device

article en

Abstract

Conducting various calculations for the heating system of a building under operational conditions is impossible without knowledge of the temperature and flow rate of the heat carrier at specific points. Contact measurement means are not always applicable, especially for small-diameter pipelines. Measurement techniques based on the theory of non-destructive thermal inspection allow for remote and timely acquisition of all necessary information. The object of the study is the floor node of the building's heating system. The subject of the study is the temperature and flow rate of the heat carrier passing through the heating device. The research aim is to determine the temperature and flow rate of the heat carrier passing through the heating device under operational conditions. The research method involves the theory of non-destructive thermal inspection, as well as heat balance and heat transfer equations for a vertical flat wall. Research findings reveal that during thermovisual inspection, the temperature of the heat carrier in the supply and return pipelines of the floor node respectively amounted to 51.6 ℃ and 49.6 ℃. The flow rate of the heat carrier through the heating device model MS-140M2-500, with a heat transfer coefficient of 8.5 W/(m²⋅K), was determined to be 195.0 kg/h. Recommendations include utilizing a thermal imager with an absolute measurement error not exceeding ±0.15 ℃ for determining the flow rate of the heat carrier through the heating device. The influence of measurement error of indoor air temperature on the accuracy of determining the heat carrier flow rate is insignificant (not exceeding ±2%). The relative error in determining the heat transfer coefficient of the heating device does not exceed ±1%.

Springer Link (Chiba Institute of Technology)
Openalex Percentile: Top 67%
Thermography and Photoacoustic Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.