Mixed-MatrixMembrane-Based Piezoelectric CO<sub>2</sub> Sensor with Self-HumidityCompensation

Monitoring the CO<sub>2</sub> concentration is crucial for assessing respiratory illnesses in humans and safeguarding the environment. The ongoing difficulty lies in achieving highly sensitive detection while also eliminating the interference caused by humidity. There is an unmet need for portable sensors with both high sensitivity and good moisture resistance to monitor CO<sub>2</sub> in real time. In this study, a novel sensor capable of capturing the piezoelectric signals induced by CO<sub>2</sub> gas is developed. A quartz crystal microbalance (QCM) coated with a mixed- matrix membrane of metal–organic framework (MOF)/polyether block amide (Pebax) is designed as a transducer to detect CO<sub>2</sub> at room temperature. The change in the concentration of CO<sub>2</sub> can be detected by the frequency shift of the QCM sensor. The sensor shows an ultrahigh sensitivity of 371.8 Hz to 1000 ppm of CO<sub>2</sub> because of the abundant polar group and nitrogen Lewis basic groups. Furthermore, the implementation of a self-humidity compensation algorithm significantly enhances the accuracy and reliability of CO<sub>2</sub> concentration monitoring by effectively addressing the issue of humidity interference. Our research underscores the immense potential of MOF/Pebax QCM sensors with self-humidity compensation ability in the field of CO<sub>2</sub> gas monitoring.

Publication Details

Journal
Figshare
Published
2025-02-06
DOI
https://doi.org/10.1021/acssensors.4c03535.s001
Primary Topic
Acoustic Wave Resonator Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Mixed-MatrixMembrane-Based Piezoelectric CO2 Sensor with Self-HumidityCompensation

Figshare
Acoustic Wave Resonator Technologies
article

Mixed-MatrixMembrane-Based Piezoelectric CO2 Sensor with Self-HumidityCompensation

article en

Abstract

Monitoring the CO<sub>2</sub> concentration is crucial for assessing respiratory illnesses in humans and safeguarding the environment. The ongoing difficulty lies in achieving highly sensitive detection while also eliminating the interference caused by humidity. There is an unmet need for portable sensors with both high sensitivity and good moisture resistance to monitor CO<sub>2</sub> in real time. In this study, a novel sensor capable of capturing the piezoelectric signals induced by CO<sub>2</sub> gas is developed. A quartz crystal microbalance (QCM) coated with a mixed- matrix membrane of metal–organic framework (MOF)/polyether block amide (Pebax) is designed as a transducer to detect CO<sub>2</sub> at room temperature. The change in the concentration of CO<sub>2</sub> can be detected by the frequency shift of the QCM sensor. The sensor shows an ultrahigh sensitivity of 371.8 Hz to 1000 ppm of CO<sub>2</sub> because of the abundant polar group and nitrogen Lewis basic groups. Furthermore, the implementation of a self-humidity compensation algorithm significantly enhances the accuracy and reliability of CO<sub>2</sub> concentration monitoring by effectively addressing the issue of humidity interference. Our research underscores the immense potential of MOF/Pebax QCM sensors with self-humidity compensation ability in the field of CO<sub>2</sub> gas monitoring.

Figshare
Openalex Percentile: Top 59%
Acoustic Wave Resonator Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.