Fast Proton NMRDetection of Aqueous Ammonia withRelaxation Agent and Nitrogen Decoupling

The Haber–Bosch process, which synthesizes ammonia (NH<sub>3</sub>) from nitrogen (N<sub>2</sub>) and hydrogen (H<sub>2</sub>), consumes approximately 2% of the global energy supply. A sustainable alternative is the direct electrochemical conversion of N<sub>2</sub> to NH<sub>3</sub>. The selectivity and activity of the electrocatalysts for this process are assessed by quantifying the NH<sub>3</sub> present in the electrolyte. Compared with other analytical methods, <sup>1</sup>H NMR offers a straightforward approach for detecting NH<sub>3</sub> (by analyzing NH<sub>4</sub><sup>+</sup>). <sup>1</sup>H NMR method can also definitely confirm that the detected ammonia originates from the electroreduction of N<sub>2</sub> by comparing results obtained from isotopically labeled <sup>15</sup>N<sub>2</sub> and regular <sup>14</sup>N<sub>2</sub> gases. This capability is unique to the <sup>1</sup>H NMR method, as no alternative approaches offer this level of specificity. However, this method suffers from low sensitivity when measuring NH<sub>4</sub><sup>+</sup> of low concentration of such as at μM or lower. To address this issue, we developed a novel approach that improves sensitivity by ∼3-fold through the introduction of <sup>14</sup>N decoupling during the <sup>1</sup>H NMR data acquisition. Recently [Kolen, M. ACS Omega 2021, 6, 5698–5704], demonstrated a ∼3.5-fold increase in sensitivity by using a 1 mM concentration of the paramagnetic relaxation agent Gd<sup>3+</sup>. By combining our <sup>14</sup>N decoupling technique with the relaxation agent Gd<sup>3+</sup>, we achieved a synergistic enhancement in sensitivity, resulting in an overall ∼10.9-fold sensitivity increase for the <sup>1</sup>H NMR detection of <sup>14</sup>NH<sub>4</sub><sup>+</sup>. This translates to a reduction in NMR detection time by a factor of ∼119 (10.9<sup>2</sup>). This significant advancement enables the fast detection of ammonia at μM concentration or lower. <sup>1</sup>H NMR of <sup>15</sup>NH<sub>4</sub><sup>+</sup> with <sup>15</sup>N decoupling was also demonstrated.

Publication Details

Journal
Figshare
Published
2025-02-20
DOI
https://doi.org/10.1021/acsomega.5c00337.s001
Primary Topic
Ammonia Synthesis and Nitrogen Reduction
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Fast Proton NMRDetection of Aqueous Ammonia withRelaxation Agent and Nitrogen Decoupling

Figshare
Ammonia Synthesis and Nitrogen Reduction
article

Fast Proton NMRDetection of Aqueous Ammonia withRelaxation Agent and Nitrogen Decoupling

article en

Abstract

The Haber–Bosch process, which synthesizes ammonia (NH<sub>3</sub>) from nitrogen (N<sub>2</sub>) and hydrogen (H<sub>2</sub>), consumes approximately 2% of the global energy supply. A sustainable alternative is the direct electrochemical conversion of N<sub>2</sub> to NH<sub>3</sub>. The selectivity and activity of the electrocatalysts for this process are assessed by quantifying the NH<sub>3</sub> present in the electrolyte. Compared with other analytical methods, <sup>1</sup>H NMR offers a straightforward approach for detecting NH<sub>3</sub> (by analyzing NH<sub>4</sub><sup>+</sup>). <sup>1</sup>H NMR method can also definitely confirm that the detected ammonia originates from the electroreduction of N<sub>2</sub> by comparing results obtained from isotopically labeled <sup>15</sup>N<sub>2</sub> and regular <sup>14</sup>N<sub>2</sub> gases. This capability is unique to the <sup>1</sup>H NMR method, as no alternative approaches offer this level of specificity. However, this method suffers from low sensitivity when measuring NH<sub>4</sub><sup>+</sup> of low concentration of such as at μM or lower. To address this issue, we developed a novel approach that improves sensitivity by ∼3-fold through the introduction of <sup>14</sup>N decoupling during the <sup>1</sup>H NMR data acquisition. Recently [Kolen, M. ACS Omega 2021, 6, 5698–5704], demonstrated a ∼3.5-fold increase in sensitivity by using a 1 mM concentration of the paramagnetic relaxation agent Gd<sup>3+</sup>. By combining our <sup>14</sup>N decoupling technique with the relaxation agent Gd<sup>3+</sup>, we achieved a synergistic enhancement in sensitivity, resulting in an overall ∼10.9-fold sensitivity increase for the <sup>1</sup>H NMR detection of <sup>14</sup>NH<sub>4</sub><sup>+</sup>. This translates to a reduction in NMR detection time by a factor of ∼119 (10.9<sup>2</sup>). This significant advancement enables the fast detection of ammonia at μM concentration or lower. <sup>1</sup>H NMR of <sup>15</sup>NH<sub>4</sub><sup>+</sup> with <sup>15</sup>N decoupling was also demonstrated.

Figshare
Responsible consumption and production
Openalex Percentile: Top 71%
Ammonia Synthesis and Nitrogen Reduction
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.