Electrospun PolyvinylChloride/UiO-66(COOH)<sub>2</sub> Nanocomposite Membranes for Efficientand Rapid Heavy Metal Removal

This study explores the effectiveness of a new composite membrane fabricated from poly­(vinyl chloride) (PVC) and the UiO-66­(COOH)<sub>2</sub> metal–organic framework (MOF) for the removal of heavy metals from water. The electrospinning technique was successfully employed to homogeneously incorporate UiO-66­(COOH)<sub>2</sub> nanocrystals into PVC, producing fibrous composite membranes. The membranes were fully characterized using several techniques such as scanning electron microscopy (SEM), capillary flow porometry, powder X-ray diffraction (PXRD), thermogravimetric analysis (TGA), and tensile strength analysis. The metal removal performance of the membranes was evaluated against lead, cadmium, and mercury in both single and mixed metal solutions at different concentrations. Results indicated a high removal efficiency (>90%) and selectivity for lead in both single and mixed solutions, especially at concentrations less than 50 ppm, along with a high adsorption capacity (<i>Q</i><sub>max</sub> = 203 mg/g). While cadmium demonstrated a lower % removal efficiency of 40% in mixed solutions compared to 80% in single solutions, it exhibited the highest adsorption capacity (<i>Q</i><sub>max</sub> = 1312 mg/g) among the three metals. For mercury, however, the decrease in removal efficiency was more pronounced, with only 10% removal in mixed systems and the lowest adsorption capacity (<i>Q</i><sub>max</sub> = 40.5 mg/g). Further experiments showed that the presence of salts, such as chlorides, nitrates, and sulfates, did not significantly affect lead and cadmium removal. Conversely, mercury removal was consistently low, regardless of these conditions. Additionally, temperature-dependent studies revealed that increasing temperature enhanced both removal efficiency and adsorption capacity, confirming that the process was spontaneous and endothermic. Interestingly, the reusability of the membranes showed a consistent removal efficiency of over 90% for lead after four cycles of use, particularly at 15 ppm, although the other metals exhibited a decrease in efficiency. Almost all pollutants showed a better fit for Langmuir and second-order kinetic models, suggesting that adsorption is a single-layered chemical adsorption process. Furthermore, a membrane holder design was fabricated using three-dimensional (3D) printing and tested to underscore the potential of PVC/MOFs composite membranes as effective materials for efficient and rapid heavy metal remediation (5 mins) in contaminated water sources. The holder significantly improved lead removal efficiency while maintaining mechanical stability, addressing the issue of handling MOFs powder alone by providing a robust matrix and support for both the MOFs and the membrane. This approach facilitates easier handling while maintaining a high efficiency, paving the way for potential industrial applications.

Publication Details

Journal
Figshare
Published
2025-02-27
DOI
https://doi.org/10.1021/acsami.4c22963.s001
Primary Topic
Adsorption and biosorption for pollutant removal
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Electrospun PolyvinylChloride/UiO-66(COOH)2 Nanocomposite Membranes for Efficientand Rapid Heavy Metal Removal

Figshare
Adsorption and biosorption for pollutant removal
article

Electrospun PolyvinylChloride/UiO-66(COOH)2 Nanocomposite Membranes for Efficientand Rapid Heavy Metal Removal

article en

Abstract

This study explores the effectiveness of a new composite membrane fabricated from poly­(vinyl chloride) (PVC) and the UiO-66­(COOH)<sub>2</sub> metal–organic framework (MOF) for the removal of heavy metals from water. The electrospinning technique was successfully employed to homogeneously incorporate UiO-66­(COOH)<sub>2</sub> nanocrystals into PVC, producing fibrous composite membranes. The membranes were fully characterized using several techniques such as scanning electron microscopy (SEM), capillary flow porometry, powder X-ray diffraction (PXRD), thermogravimetric analysis (TGA), and tensile strength analysis. The metal removal performance of the membranes was evaluated against lead, cadmium, and mercury in both single and mixed metal solutions at different concentrations. Results indicated a high removal efficiency (>90%) and selectivity for lead in both single and mixed solutions, especially at concentrations less than 50 ppm, along with a high adsorption capacity (<i>Q</i><sub>max</sub> = 203 mg/g). While cadmium demonstrated a lower % removal efficiency of 40% in mixed solutions compared to 80% in single solutions, it exhibited the highest adsorption capacity (<i>Q</i><sub>max</sub> = 1312 mg/g) among the three metals. For mercury, however, the decrease in removal efficiency was more pronounced, with only 10% removal in mixed systems and the lowest adsorption capacity (<i>Q</i><sub>max</sub> = 40.5 mg/g). Further experiments showed that the presence of salts, such as chlorides, nitrates, and sulfates, did not significantly affect lead and cadmium removal. Conversely, mercury removal was consistently low, regardless of these conditions. Additionally, temperature-dependent studies revealed that increasing temperature enhanced both removal efficiency and adsorption capacity, confirming that the process was spontaneous and endothermic. Interestingly, the reusability of the membranes showed a consistent removal efficiency of over 90% for lead after four cycles of use, particularly at 15 ppm, although the other metals exhibited a decrease in efficiency. Almost all pollutants showed a better fit for Langmuir and second-order kinetic models, suggesting that adsorption is a single-layered chemical adsorption process. Furthermore, a membrane holder design was fabricated using three-dimensional (3D) printing and tested to underscore the potential of PVC/MOFs composite membranes as effective materials for efficient and rapid heavy metal remediation (5 mins) in contaminated water sources. The holder significantly improved lead removal efficiency while maintaining mechanical stability, addressing the issue of handling MOFs powder alone by providing a robust matrix and support for both the MOFs and the membrane. This approach facilitates easier handling while maintaining a high efficiency, paving the way for potential industrial applications.

Figshare
Clean water and sanitation
Openalex Percentile: Top 62%
Adsorption and biosorption for pollutant removal
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.