A SprayablePolyelectrolyte Coating to Mitigate theForeign Body Response of Implants

The foreign body response (FBR) presents a significant challenge to biomedical implants, leading to fibrotic capsule formation that compromises implant functionality. In this study, we report a straightforward method for fabricating stable anti-fibrotic polyelectrolyte coatings on implant surfaces using industrialized ultrasonic spraying technology. The coating thickness and surface charge can be adjusted through variations in spraying time and polyelectrolyte ratio, respectively. We investigate the fibrotic response of polyelectrolyte-coated implants with varying surface charges and thicknesses. Our findings reveal that surface charge significantly influences the fibrotic response, while electronegative polyelectrolyte coatings most effectively inhibit FBR compared to electrically neutral, positively charged, and uncoated surfaces. Meanwhile, coating thickness beyond 10 μm resulted in thinner capsules than coatings at a 1 μm or nanometer scale. The simple and versatile polyelectrolyte coating method reported here holds great potential to enhance and extend the functionality of implants in a mass-produced manner by mitigating host responses to implantable biomaterials.

Publication Details

Journal
Figshare
Published
2025-03-27
DOI
https://doi.org/10.1021/acs.langmuir.5c00868.s001
Primary Topic
Polymer Surface Interaction Studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A SprayablePolyelectrolyte Coating to Mitigate theForeign Body Response of Implants

Figshare
Polymer Surface Interaction Studies
article

A SprayablePolyelectrolyte Coating to Mitigate theForeign Body Response of Implants

article en

Abstract

The foreign body response (FBR) presents a significant challenge to biomedical implants, leading to fibrotic capsule formation that compromises implant functionality. In this study, we report a straightforward method for fabricating stable anti-fibrotic polyelectrolyte coatings on implant surfaces using industrialized ultrasonic spraying technology. The coating thickness and surface charge can be adjusted through variations in spraying time and polyelectrolyte ratio, respectively. We investigate the fibrotic response of polyelectrolyte-coated implants with varying surface charges and thicknesses. Our findings reveal that surface charge significantly influences the fibrotic response, while electronegative polyelectrolyte coatings most effectively inhibit FBR compared to electrically neutral, positively charged, and uncoated surfaces. Meanwhile, coating thickness beyond 10 μm resulted in thinner capsules than coatings at a 1 μm or nanometer scale. The simple and versatile polyelectrolyte coating method reported here holds great potential to enhance and extend the functionality of implants in a mass-produced manner by mitigating host responses to implantable biomaterials.

Figshare
Industry, innovation and infrastructure
Openalex Percentile: Top 62%
Polymer Surface Interaction Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

A SprayablePolyelectrolyte Coating to Mitigate theForeign Body Response of Implants · Figshare (2025) | TGRS Research Map | TGRS