SimultaneousMeasurement of Total Ammonia Nitrogenand Free Ammonia via Integrated Electrochemical AcidificationOptodeFlow Cell

The accurate measurement of total ammonia nitrogen (TAN) and free ammonia is crucial for various environmental, biomedical and industrial applications. We present a novel integrated system combining electrochemical water splitting with ammonia optodes to simultaneously measure TAN and free ammonia. Water electrolysis induces localized pH shifts, altering the ammonia speciation in the sample solution: an increase in pH near the cathode leads to conversion of NH<sub>4</sub><sup>+</sup> to NH<sub>3</sub>, enabling the measurement of TAN. Concurrently, a decrease in pH near the anode reduces the NH<sub>3</sub> concentration to zero, enabling real-time zero calibration. In areas unaffected by these pH changes, the optode readout can effectively measure free NH<sub>3</sub>. The system demonstrates a measurement range of 0–300 mg·L<sup>–1</sup> for both TAN and NH<sub>3</sub>, with a complete measurement cycle requiring only 6 min. The method was validated through the analysis of urine samples, showcasing its potential for real-time monitoring in clinical and environmental settings. The electrochemical speciation shifting allows for precise TAN measurement, while the zero-point calibration provided by the anode enhances the method’s robustness and reliability. Overall, this study introduces a versatile and efficient approach for the simultaneous determination of TAN and NH<sub>3</sub>, offering significant improvements in speed and operational simplicity.

Publication Details

Journal
Figshare
Published
2025-03-21
DOI
https://doi.org/10.1021/acs.analchem.4c05994.s001
Primary Topic
Analytical Chemistry and Sensors
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

SimultaneousMeasurement of Total Ammonia Nitrogenand Free Ammonia via Integrated Electrochemical AcidificationOptodeFlow Cell

Figshare
Analytical Chemistry and Sensors
article

SimultaneousMeasurement of Total Ammonia Nitrogenand Free Ammonia via Integrated Electrochemical AcidificationOptodeFlow Cell

article en

Abstract

The accurate measurement of total ammonia nitrogen (TAN) and free ammonia is crucial for various environmental, biomedical and industrial applications. We present a novel integrated system combining electrochemical water splitting with ammonia optodes to simultaneously measure TAN and free ammonia. Water electrolysis induces localized pH shifts, altering the ammonia speciation in the sample solution: an increase in pH near the cathode leads to conversion of NH<sub>4</sub><sup>+</sup> to NH<sub>3</sub>, enabling the measurement of TAN. Concurrently, a decrease in pH near the anode reduces the NH<sub>3</sub> concentration to zero, enabling real-time zero calibration. In areas unaffected by these pH changes, the optode readout can effectively measure free NH<sub>3</sub>. The system demonstrates a measurement range of 0–300 mg·L<sup>–1</sup> for both TAN and NH<sub>3</sub>, with a complete measurement cycle requiring only 6 min. The method was validated through the analysis of urine samples, showcasing its potential for real-time monitoring in clinical and environmental settings. The electrochemical speciation shifting allows for precise TAN measurement, while the zero-point calibration provided by the anode enhances the method’s robustness and reliability. Overall, this study introduces a versatile and efficient approach for the simultaneous determination of TAN and NH<sub>3</sub>, offering significant improvements in speed and operational simplicity.

Figshare
Clean water and sanitation
Openalex Percentile: Top 54%
Analytical Chemistry and Sensors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

SimultaneousMeasurement of Total Ammonia Nitrogenand Free Ammonia via Integrated Electrochemical AcidificationOptodeFlow Cell · Figshare (2025) | TGRS Research Map | TGRS