Increased Sensitivityin VOC Detection by Using aNovel Photoinduced Multiple Ionization Mass Spectrometry

Proton transfer reaction mass spectrometry (PTR-MS) is an important online monitoring technique for volatile organic compounds (VOCs). VOCs have the characteristics of many types, rapid change, and low concentration. Enhancing the detection sensitivity and expanding the detection range of VOCs have been key challenges in PTR-MS research. In this work, we have developed and characterized a novel photoinduced multiple ionizations (PMI) source, which consists of four direct current (DC) vacuum ultraviolet Kr lamps and a V-shaped focusing quadrupole ion funnel (FQ-IF) drift tube. The novel PMI source has four ionization processes: proton transfer reaction, charge transfer reaction, single photon ionization, and photoelectron impact ionization. It is capable of detecting VOCs detectable by conventional PTR-MS via the PTR, as well as VOCs (carbon disulfide and acetylene) that are difficult to detect by conventional PTR-MS through other ionization processes, thus effectively expanding the detection range. In further comparative experiments, the improvements in sensitivity for the PMI-MS in FQ-IF mode range from 122.5 to 647.7 times compared to the PTR-MS in DC mode (conventional PTR-MS) for 12 test VOCs. Notably, the sensitivities of four BTEXs in 12 VOCs were more than 10,000 cps/ppb. Moreover, compared with PTR-MS in DC mode, the LOD of PMI-MS in FQ-IF mode for 12 test VOCs increased by 26–128.6 times. PMI-MS not only expands the detection range but also improves the sensitivity by 2 orders of magnitude, which would provide an important tool for the detection of ultratrace VOCs.

Publication Details

Journal
Figshare
Published
2025-02-17
DOI
https://doi.org/10.1021/acs.analchem.4c05873.s001
Primary Topic
Mass Spectrometry Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Increased Sensitivityin VOC Detection by Using aNovel Photoinduced Multiple Ionization Mass Spectrometry

Figshare
Mass Spectrometry Techniques and Applications
article

Increased Sensitivityin VOC Detection by Using aNovel Photoinduced Multiple Ionization Mass Spectrometry

article en

Abstract

Proton transfer reaction mass spectrometry (PTR-MS) is an important online monitoring technique for volatile organic compounds (VOCs). VOCs have the characteristics of many types, rapid change, and low concentration. Enhancing the detection sensitivity and expanding the detection range of VOCs have been key challenges in PTR-MS research. In this work, we have developed and characterized a novel photoinduced multiple ionizations (PMI) source, which consists of four direct current (DC) vacuum ultraviolet Kr lamps and a V-shaped focusing quadrupole ion funnel (FQ-IF) drift tube. The novel PMI source has four ionization processes: proton transfer reaction, charge transfer reaction, single photon ionization, and photoelectron impact ionization. It is capable of detecting VOCs detectable by conventional PTR-MS via the PTR, as well as VOCs (carbon disulfide and acetylene) that are difficult to detect by conventional PTR-MS through other ionization processes, thus effectively expanding the detection range. In further comparative experiments, the improvements in sensitivity for the PMI-MS in FQ-IF mode range from 122.5 to 647.7 times compared to the PTR-MS in DC mode (conventional PTR-MS) for 12 test VOCs. Notably, the sensitivities of four BTEXs in 12 VOCs were more than 10,000 cps/ppb. Moreover, compared with PTR-MS in DC mode, the LOD of PMI-MS in FQ-IF mode for 12 test VOCs increased by 26–128.6 times. PMI-MS not only expands the detection range but also improves the sensitivity by 2 orders of magnitude, which would provide an important tool for the detection of ultratrace VOCs.

Figshare
Openalex Percentile: Top 63%
Mass Spectrometry Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Increased Sensitivityin VOC Detection by Using aNovel Photoinduced Multiple Ionization Mass Spectrometry · Figshare (2025) | TGRS Research Map | TGRS