Mechanical Performance of Thoracic Aortic Stent-Grafts: An In Vitro and In Silico Study

Thoracic endovascular aortic repair (TEVAR) is the standard of care for thoracic aortic pathologies, and its clinical success is related to the choice of stent-grafts (SGs). In this study, we conducted a comprehensive assessment of four commercial SGs (Valiant Captivia (VC), Terumo RelayPro Bare Stent (TBS), Cook Zenith Alpha (CZA), and Gore CTAG (CTAG)) to evaluate their mechanical performance in idealised and patient-specific conditions. High-fidelity finite element models were developed and validated against experimental tests and in vitro TEVAR procedures in 3D-printed rigid phantoms. The validation showed strong agreement between simulations and experiments (average error < 5%).Then, the SGs were virtually deployed in two aortic models to investigate device-wall interaction through geometrical and mechanical parameters. A greater metal density led to increased graft apposition (up to 94%) and increased radial forces (up to 354 N vs 116N). Conversely, sparser metal structures produced lower but more localised stress regions: maximum values of 0.25 MPa versus 0.49 MPa with denser metal. Higher stresses may contribute to improved device fixation and, when associated with greater apposition, may reduce the risk of endoleak. Nevertheless, high stresses could potentially induce long-term vascular remodelling.These results underscore the influence of SG's design on TEVAR outcomes and support the integration of validated computational simulations into pre-operative planning. The SG performance varied across patient anatomies: this study highlights the importance of personalized device selection and establishes a foundation for using in silico methods to optimize TEVAR strategies and mitigate procedural risks.

Institutions

Publication Details

Journal
Annals of Biomedical Engineering
Published
2025-12-21
DOI
https://doi.org/10.1007/s10439-025-03949-y
Primary Topic
Aortic aneurysm repair treatments
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Mechanical Performance of Thoracic Aortic Stent-Grafts: An In Vitro and In Silico Study

Annals of Biomedical Engineering
Aortic aneurysm repair treatments
article

Mechanical Performance of Thoracic Aortic Stent-Grafts: An In Vitro and In Silico Study

article en

Abstract

Thoracic endovascular aortic repair (TEVAR) is the standard of care for thoracic aortic pathologies, and its clinical success is related to the choice of stent-grafts (SGs). In this study, we conducted a comprehensive assessment of four commercial SGs (Valiant Captivia (VC), Terumo RelayPro Bare Stent (TBS), Cook Zenith Alpha (CZA), and Gore CTAG (CTAG)) to evaluate their mechanical performance in idealised and patient-specific conditions. High-fidelity finite element models were developed and validated against experimental tests and in vitro TEVAR procedures in 3D-printed rigid phantoms. The validation showed strong agreement between simulations and experiments (average error < 5%).Then, the SGs were virtually deployed in two aortic models to investigate device-wall interaction through geometrical and mechanical parameters. A greater metal density led to increased graft apposition (up to 94%) and increased radial forces (up to 354 N vs 116N). Conversely, sparser metal structures produced lower but more localised stress regions: maximum values of 0.25 MPa versus 0.49 MPa with denser metal. Higher stresses may contribute to improved device fixation and, when associated with greater apposition, may reduce the risk of endoleak. Nevertheless, high stresses could potentially induce long-term vascular remodelling.These results underscore the influence of SG's design on TEVAR outcomes and support the integration of validated computational simulations into pre-operative planning. The SG performance varied across patient anatomies: this study highlights the importance of personalized device selection and establishes a foundation for using in silico methods to optimize TEVAR strategies and mitigate procedural risks.

Annals of Biomedical Engineering
University of Milan (IT), Université de Haute-Alsace (FR), Fondazione IRCCS Ca' Granda Ospedale Maggiore Policlinico (IT), Ente Regionale per i Servizi all'Agricoltura e alle Foreste (IT), St. Antonius Ziekenhuis (NL), Université de Strasbourg (FR), Politecnico di Milano (IT)
European Commission
Openalex Percentile: Top 40%
Aortic aneurysm repair treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.