CFD investigation of indoor airflow and heat removal during night cooling with ceiling and attic ventilation in a residential building

• Assessment of heat removal and air exchange in a dwelling in a hot-humid climate. • Cooling potential of a perforated ceiling with attic ventilation was investigated. • CFD simulations with 3D steady RANS were employed under non-isothermal conditions. • Ceiling and attic ventilation result in 98% higher heat removal effectiveness. • Ceiling and attic ventilation decrease the indoor air temperature with up to 1.5°C. This paper investigates the cooling potential of a perforated ceiling as part of a night-time ventilation technique for residential buildings in tropical climates. 3D steady Reynolds-averaged Navier-Stokes computational fluid dynamics simulations were carried out under non-isothermal conditions (wind and buoyancy-driven ventilation) for an isolated realistic single-story residential building with internal partitions and a pitched roof. Three different building ventilation configurations were assessed, i.e. cross-ventilation through window openings on the windward and leeward walls (C1), configuration C1 but with a perforated ceiling and attic ventilation (C2), single-sided ventilation through the windward window opening combined with a perforated ceiling and attic ventilation (C3). The results show that C2 performs better than C1 and C3, as it allows the most efficient heat removal from the occupied zone, resulting in a reduction of the volume-average mean air temperature within the rooms. Configuration C2 resulted in a 98% higher heat removal effectiveness (HRE) and a 20% higher air exchange rate (ACH) than the reference case (C1). Decreasing the porosity of the perforated ceiling for C2, from φ = 40% to φ = 33%, resulted in a reduction of HRE and ACH of 32% and 7%, respectively. Furthermore, different approach-flow angles (i.e. α = -60°; α = -30°; α = 0°; α = 30°; α = 60°) did not significantly affect HRE and ACH within the unpartitioned side of the building (Room 1 (R1)), while a substantial effect was found for the partitioned side (R2/R3). Overall, C2 outperforms C1 and C3 with respect to heat removal.

Institutions

Publication Details

Journal
Building and Environment
Published
2025-12-21
DOI
https://doi.org/10.1016/j.buildenv.2025.114159
Primary Topic
Wind and Air Flow Studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

CFD investigation of indoor airflow and heat removal during night cooling with ceiling and attic ventilation in a residential building

Building and Environment
Wind and Air Flow Studies
article

CFD investigation of indoor airflow and heat removal during night cooling with ceiling and attic ventilation in a residential building

article en

Abstract

• Assessment of heat removal and air exchange in a dwelling in a hot-humid climate. • Cooling potential of a perforated ceiling with attic ventilation was investigated. • CFD simulations with 3D steady RANS were employed under non-isothermal conditions. • Ceiling and attic ventilation result in 98% higher heat removal effectiveness. • Ceiling and attic ventilation decrease the indoor air temperature with up to 1.5°C. This paper investigates the cooling potential of a perforated ceiling as part of a night-time ventilation technique for residential buildings in tropical climates. 3D steady Reynolds-averaged Navier-Stokes computational fluid dynamics simulations were carried out under non-isothermal conditions (wind and buoyancy-driven ventilation) for an isolated realistic single-story residential building with internal partitions and a pitched roof. Three different building ventilation configurations were assessed, i.e. cross-ventilation through window openings on the windward and leeward walls (C1), configuration C1 but with a perforated ceiling and attic ventilation (C2), single-sided ventilation through the windward window opening combined with a perforated ceiling and attic ventilation (C3). The results show that C2 performs better than C1 and C3, as it allows the most efficient heat removal from the occupied zone, resulting in a reduction of the volume-average mean air temperature within the rooms. Configuration C2 resulted in a 98% higher heat removal effectiveness (HRE) and a 20% higher air exchange rate (ACH) than the reference case (C1). Decreasing the porosity of the perforated ceiling for C2, from φ = 40% to φ = 33%, resulted in a reduction of HRE and ACH of 32% and 7%, respectively. Furthermore, different approach-flow angles (i.e. α = -60°; α = -30°; α = 0°; α = 30°; α = 60°) did not significantly affect HRE and ACH within the unpartitioned side of the building (Room 1 (R1)), while a substantial effect was found for the partitioned side (R2/R3). Overall, C2 outperforms C1 and C3 with respect to heat removal.

Building and EnvironmentVol. 291
Heriot-Watt University (GB), Universitas Islam Makassar (ID), Eindhoven University of Technology (NL), KU Leuven (BE)
Openalex Percentile: Top 60%
Wind and Air Flow Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.