A novel method for acoustic modeling of cranial bone based on the porosity index

Transcranial ultrasound stimulation (TUS) has emerged as a clinically validated neuromodulation technique. Particularly, phased array ultrasound can be applied in TUS to focus on the cortex or deep brain non-invasively, such as the ventral intermediate thalamic nucleus (VIM) and Precuneus (PCu) region for the treatment of essential tremor (ET) and Alzheimer Disease (AD). Current TUS treatment planning relies on computed tomography (CT)-derived skull porosity measurements, which involve patient radiation exposure and potential registration errors. This study proposes a Porosity Index (PI)-based method, derived from Ultrashort Echo Time (UTE) Magnetic Resonance (MR) images, for establishing skull acoustic models as a viable alternative, aiming to eliminate these limitations. Acoustic simulations using the K-Wave open-source platform were performed to validate the PI method's accuracy in predicting skull porosity and simulating focal distributions compared to CT. Focal spot characteristics were quantified using five metrics: peak intensity, target intensity, focal positioning error, Dice similarity coefficient, and Pearson correlation coefficient between CT- and PI-based simulation results. Statistical differences between these metrics were assessed using Tukey's multiple comparisons test. Quantitative comparisons against the gold-standard CT approach demonstrated comparable performance in peak focal intensity (deviation < 5%) and spatial pressure distribution patterns (Dice coefficient > 0.82). No significant differences (p > 0.05) were observed for any of the evaluated metrics. Our findings demonstrate that both the sound pressure distribution and prediction of the porosity are comparable with those from the reference CT. Using the PI to replace the traditional CT porosity has high feasibility and can achieve the purpose of reducing unnecessary radiation exposure and registration error for patients.

Institutions

Publication Details

Journal
Scientific Reports
Published
2025-12-21
DOI
https://doi.org/10.1038/s41598-025-33411-x
Primary Topic
Ultrasound and Hyperthermia Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A novel method for acoustic modeling of cranial bone based on the porosity index

Scientific Reports
Ultrasound and Hyperthermia Applications
article

A novel method for acoustic modeling of cranial bone based on the porosity index

article en

Abstract

Transcranial ultrasound stimulation (TUS) has emerged as a clinically validated neuromodulation technique. Particularly, phased array ultrasound can be applied in TUS to focus on the cortex or deep brain non-invasively, such as the ventral intermediate thalamic nucleus (VIM) and Precuneus (PCu) region for the treatment of essential tremor (ET) and Alzheimer Disease (AD). Current TUS treatment planning relies on computed tomography (CT)-derived skull porosity measurements, which involve patient radiation exposure and potential registration errors. This study proposes a Porosity Index (PI)-based method, derived from Ultrashort Echo Time (UTE) Magnetic Resonance (MR) images, for establishing skull acoustic models as a viable alternative, aiming to eliminate these limitations. Acoustic simulations using the K-Wave open-source platform were performed to validate the PI method's accuracy in predicting skull porosity and simulating focal distributions compared to CT. Focal spot characteristics were quantified using five metrics: peak intensity, target intensity, focal positioning error, Dice similarity coefficient, and Pearson correlation coefficient between CT- and PI-based simulation results. Statistical differences between these metrics were assessed using Tukey's multiple comparisons test. Quantitative comparisons against the gold-standard CT approach demonstrated comparable performance in peak focal intensity (deviation < 5%) and spatial pressure distribution patterns (Dice coefficient > 0.82). No significant differences (p > 0.05) were observed for any of the evaluated metrics. Our findings demonstrate that both the sound pressure distribution and prediction of the porosity are comparable with those from the reference CT. Using the PI to replace the traditional CT porosity has high feasibility and can achieve the purpose of reducing unnecessary radiation exposure and registration error for patients.

Scientific ReportsVol. 16(1)
Chinese Academy of Medical Sciences & Peking Union Medical College (CN), Sichuan University (CN), Sir Run Run Shaw Hospital (CN), West China Hospital of Sichuan University (CN), Zhejiang Cancer Hospital (CN), Sichuan Cancer Hospital (CN), Chengdu University (CN), Zhejiang University (CN)
Openalex Percentile: Top 59%
Ultrasound and Hyperthermia Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.