Use of the ExoSeal Vascular Closure Device in Patients With Peripheral Artery Disease: Risk Analysis of Deployment Failure and Prolonged Hemostasis

ObjectivesEndovascular treatment (EVT) of lower extremity artery disease (LEAD) is minimally invasive and has good safety and efficacy. Puncture site complications are common in EVT, but these and the hemostatic time have been reduced by newer hemostatic devices such as ExoSeal. However, factors affecting poor outcomes after use of ExoSeal are unclear. Therefore, the purpose of this study is to identify these factors after ExoSeal deployment in EVT.Material and MethodsA retrospective study was performed for 868 cases in which hemostasis was attempted using ExoSeal between 2019 and 2023. Factors affecting deployment failure and prolonged hemostatic time after ExoSeal were assessed.ResultsThe 868 subjects (569 males, 66%) had a median age of 77 [72-83] years. A femoral antegrade approach was used in 548 cases (63%), with use of a 6Fr sheath in most cases (99%). The lesions were in the femoropopliteal (<i>n</i> = 387, 44%) and infrapopliteal (<i>n</i> = 359, 41%) arteries. The technical success rate of EVT was 97%. ExoSeal was successfully deployed in 812 cases (94%). Cases in which ExoSeal deployment was unsuccessful had significantly more frequent proximal stenting (9% vs 20%, <i>P</i> = .01). In the entire cohort, there were 6 (.69%) puncture site complications. Of the 812 cases with successful deployment, the manual compression hemostasis time was prolonged (>10 min) in 51 cases (6%). Hemostatic time was significantly prolonged in cases with proximal stenting or intimal thickening at the puncture site (both, <i>P</i> < .001).ConclusionThese results show that ExoSeal is a useful device. However, deployment failure and prolonged hemostatic time were caused by a proximal stent or intimal thickening of the puncture site, and use of hemostatic devices in such cases requires further investigation.

Institutions

Publication Details

Journal
Vascular and Endovascular Surgery
Published
2025-12-19
DOI
https://doi.org/10.1177/15385744251409971
Primary Topic
Peripheral Artery Disease Management
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Use of the ExoSeal Vascular Closure Device in Patients With Peripheral Artery Disease: Risk Analysis of Deployment Failure and Prolonged Hemostasis

Vascular and Endovascular Surgery
Peripheral Artery Disease Management
article

Use of the ExoSeal Vascular Closure Device in Patients With Peripheral Artery Disease: Risk Analysis of Deployment Failure and Prolonged Hemostasis

article en

Abstract

ObjectivesEndovascular treatment (EVT) of lower extremity artery disease (LEAD) is minimally invasive and has good safety and efficacy. Puncture site complications are common in EVT, but these and the hemostatic time have been reduced by newer hemostatic devices such as ExoSeal. However, factors affecting poor outcomes after use of ExoSeal are unclear. Therefore, the purpose of this study is to identify these factors after ExoSeal deployment in EVT.Material and MethodsA retrospective study was performed for 868 cases in which hemostasis was attempted using ExoSeal between 2019 and 2023. Factors affecting deployment failure and prolonged hemostatic time after ExoSeal were assessed.ResultsThe 868 subjects (569 males, 66%) had a median age of 77 [72-83] years. A femoral antegrade approach was used in 548 cases (63%), with use of a 6Fr sheath in most cases (99%). The lesions were in the femoropopliteal (<i>n</i> = 387, 44%) and infrapopliteal (<i>n</i> = 359, 41%) arteries. The technical success rate of EVT was 97%. ExoSeal was successfully deployed in 812 cases (94%). Cases in which ExoSeal deployment was unsuccessful had significantly more frequent proximal stenting (9% vs 20%, <i>P</i> = .01). In the entire cohort, there were 6 (.69%) puncture site complications. Of the 812 cases with successful deployment, the manual compression hemostasis time was prolonged (>10 min) in 51 cases (6%). Hemostatic time was significantly prolonged in cases with proximal stenting or intimal thickening at the puncture site (both, <i>P</i> < .001).ConclusionThese results show that ExoSeal is a useful device. However, deployment failure and prolonged hemostatic time were caused by a proximal stent or intimal thickening of the puncture site, and use of hemostatic devices in such cases requires further investigation.

Vascular and Endovascular Surgery
Hiroshima General Hospital (JP), Hiroshima University Hospital (JP)
Openalex Percentile: Top 39%
Peripheral Artery Disease Management
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Use of the ExoSeal Vascular Closure Device in Patients With Peripheral Artery Disease: Risk Analysis of Deployment Failure and Prolonged Hemostasis · Vascular and Endovascular Surgery (2025) | TGRS Research Map | TGRS