A novel ultrasensitive electrochemical genosensor based on PtNPs/EEGO-AGs/AuNPs nanoassembly for rapid detection of HCMV miRNA

MicroRNAs (miRNAs) are stable and accessible biomarkers for disease diagnosis. Elevated levels of human cytomegalovirus (HCMV)-encoded miRNA-UL22A-5p (miR-UL22A-5p) are associated with virologic recurrence in transplant patients with HCMV infection and can serve as a prognostic marker. Here, we introduce the first electrochemical genosensing platform for the sensitive and accurate detection of miR-UL22A-5p in serum samples. This platform employs a ratiometric strategy to improve probe specificity within complex serum matrices. A new nanocomposite consisting of platinum nanoparticles, effectively oxidised graphene oxide aerogels, and gold nanoparticles (PtNPs/EEGO-AGs/AuNPs) was electrodeposited onto a glassy carbon electrode (GCE). This design boosts sensor performance: PtNPs provide high electrocatalytic activity for signal amplification, EEGO-AGs offer antifouling properties to reduce interference from biological matrices while serving as a substrate for further modification, and AuNPs facilitate stable thiol-mediated attachment of single-stranded DNA probes. Under optimal conditions, the nanobiosensor demonstrated a linear detection range from 10<sup>- 12</sup> to 10<sup>- 5</sup> M, with a detection limit (LOD) of 6.1 × 10<sup>- 13</sup> M and a quantification limit (LOQ) of 2 × 10<sup>- 12</sup> M in human serum. Reproducibility was acceptable, with a standard deviation of 1.8%. To assess its quantitative ability and detection sensitivity, serum samples spiked with miR-UL22A-5p were analysed simultaneously with the biosensor and qRT-PCR, showing that the biosensor has a lower detection limit. This biosensor holds significant potential for clinical use as a sensitive tool for early HCMV detection in transplant patients. However, further validation through prospective clinical trials is necessary to confirm its effectiveness and impact on patient outcomes.

Institutions

Publication Details

Journal
BMC Chemistry
Published
2025-12-20
DOI
https://doi.org/10.1186/s13065-025-01699-5
Primary Topic
Advanced biosensing and bioanalysis techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A novel ultrasensitive electrochemical genosensor based on PtNPs/EEGO-AGs/AuNPs nanoassembly for rapid detection of HCMV miRNA

BMC Chemistry
Advanced biosensing and bioanalysis techniques
article

A novel ultrasensitive electrochemical genosensor based on PtNPs/EEGO-AGs/AuNPs nanoassembly for rapid detection of HCMV miRNA

article en

Abstract

MicroRNAs (miRNAs) are stable and accessible biomarkers for disease diagnosis. Elevated levels of human cytomegalovirus (HCMV)-encoded miRNA-UL22A-5p (miR-UL22A-5p) are associated with virologic recurrence in transplant patients with HCMV infection and can serve as a prognostic marker. Here, we introduce the first electrochemical genosensing platform for the sensitive and accurate detection of miR-UL22A-5p in serum samples. This platform employs a ratiometric strategy to improve probe specificity within complex serum matrices. A new nanocomposite consisting of platinum nanoparticles, effectively oxidised graphene oxide aerogels, and gold nanoparticles (PtNPs/EEGO-AGs/AuNPs) was electrodeposited onto a glassy carbon electrode (GCE). This design boosts sensor performance: PtNPs provide high electrocatalytic activity for signal amplification, EEGO-AGs offer antifouling properties to reduce interference from biological matrices while serving as a substrate for further modification, and AuNPs facilitate stable thiol-mediated attachment of single-stranded DNA probes. Under optimal conditions, the nanobiosensor demonstrated a linear detection range from 10<sup>- 12</sup> to 10<sup>- 5</sup> M, with a detection limit (LOD) of 6.1 × 10<sup>- 13</sup> M and a quantification limit (LOQ) of 2 × 10<sup>- 12</sup> M in human serum. Reproducibility was acceptable, with a standard deviation of 1.8%. To assess its quantitative ability and detection sensitivity, serum samples spiked with miR-UL22A-5p were analysed simultaneously with the biosensor and qRT-PCR, showing that the biosensor has a lower detection limit. This biosensor holds significant potential for clinical use as a sensitive tool for early HCMV detection in transplant patients. However, further validation through prospective clinical trials is necessary to confirm its effectiveness and impact on patient outcomes.

BMC ChemistryVol. 20(1)
Iran University of Medical Sciences (IR), Tabriz University of Medical Sciences (IR)
Openalex Percentile: Top 62%
Advanced biosensing and bioanalysis techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

A novel ultrasensitive electrochemical genosensor based on PtNPs/EEGO-AGs/AuNPs nanoassembly for rapid detection of HCMV miRNA · BMC Chemistry (2025) | TGRS Research Map | TGRS