Measurement of Internal Jugular Vein Distensibility Index by Ultrasound as Alternative of Echocardiography for Prediction of Fluid Responsiveness in Postpartum Preeclamptic Patients

Background: No evidence existed examining the role of the internal jugular vein distensibility index as a dynamic predictor of fluid responsiveness in preeclamptic patients during the postpartum period.Aim: To discuss the predictive ability of the internal jugular vein distensibility index for identifying fluid responsiveness in preeclamptic patients during the postpartum period.Methods: This study was conducted on 66 postpartum preeclamptic patients. The primary outcome included changes in cardiac index and internal jugular vein distensibility index in response to fluid administration. Secondary outcomes included the severity of preeclampsia and diagnostic accuracy of the internal jugular vein distensibility index to detect fluid responsiveness. A fluid challenge with 7 ml/kg of Ringer’s lactate was administered over 15 minutes, and patients were classified as fluid responders or non-responders. For responders, the fluid challenge and measurements were repeated until they transitioned to non-responder status.Results: This study demonstrated a statistically significant positive correlation between Δ cardiac index and internal jugular vein distensibility index at the first and second challenges (r = 0.802, P = 0.001 and r = 0.632, P = 0.03), respectively. Nevertheless, no significant correlation was found at the third and fourth challenges. Internal jugular vein distensibility index at a cutoff value of 17% had a sensitivity of 88% and specificity of 78% (AUC= 0.852, P= 0.001).Conclusion: Measurement of the internal jugular vein distensibility index can serve as a simple and efficient bedside test for promptly and non-invasively diagnosing and monitoring volume responsiveness in preeclamptic patients postpartum.

Publication Details

Journal
Al-Azhar International Medical Journal /Al-Azhar International Medical Journal
Published
2024-11-01
DOI
https://doi.org/10.21608/aimj.2024.470478
Primary Topic
Pregnancy and preeclampsia studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Measurement of Internal Jugular Vein Distensibility Index by Ultrasound as Alternative of Echocardiography for Prediction of Fluid Responsiveness in Postpartum Preeclamptic Patients

Al-Azhar International Medical Journal /Al-Azhar International Medical Journal
Pregnancy and preeclampsia studies
article

Measurement of Internal Jugular Vein Distensibility Index by Ultrasound as Alternative of Echocardiography for Prediction of Fluid Responsiveness in Postpartum Preeclamptic Patients

article en

Abstract

Background: No evidence existed examining the role of the internal jugular vein distensibility index as a dynamic predictor of fluid responsiveness in preeclamptic patients during the postpartum period.Aim: To discuss the predictive ability of the internal jugular vein distensibility index for identifying fluid responsiveness in preeclamptic patients during the postpartum period.Methods: This study was conducted on 66 postpartum preeclamptic patients. The primary outcome included changes in cardiac index and internal jugular vein distensibility index in response to fluid administration. Secondary outcomes included the severity of preeclampsia and diagnostic accuracy of the internal jugular vein distensibility index to detect fluid responsiveness. A fluid challenge with 7 ml/kg of Ringer’s lactate was administered over 15 minutes, and patients were classified as fluid responders or non-responders. For responders, the fluid challenge and measurements were repeated until they transitioned to non-responder status.Results: This study demonstrated a statistically significant positive correlation between Δ cardiac index and internal jugular vein distensibility index at the first and second challenges (r = 0.802, P = 0.001 and r = 0.632, P = 0.03), respectively. Nevertheless, no significant correlation was found at the third and fourth challenges. Internal jugular vein distensibility index at a cutoff value of 17% had a sensitivity of 88% and specificity of 78% (AUC= 0.852, P= 0.001).Conclusion: Measurement of the internal jugular vein distensibility index can serve as a simple and efficient bedside test for promptly and non-invasively diagnosing and monitoring volume responsiveness in preeclamptic patients postpartum.

Al-Azhar International Medical Journal /Al-Azhar International Medical JournalVol. 2024(11)
Openalex Percentile: Top 60%
Pregnancy and preeclampsia studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.