Mitigating Muscle Fatigue in Upper-Limb Prosthesis Users Through Exoskeletal Weight Compensation

Prosthesis users often experience muscle fatigue and reduced control due to the weight of the device, contributing to high abandonment rates. This study investigates the effects of integrating a soft exoskeleton with a myoelectric prosthesis on upper-limb muscle fatigue and user experience. Nine non-disabled participants performed four functional tasks: drinking from a cup, using a Fork, lifting a box, and reaching overhead, using the prosthesis alone and in combination with the exoskeleton. Muscle activity was recorded via surface electromyography, and perceived exertion was measured using the Borg scale. Kinematics and workload were also assessed through motion capture and the NASA-TLX questionnaire. Usability was evaluated using the System Usability Scale (SUS). Results showed that exoskeleton assistance significantly reduced muscle activation, particularly in the Deltoid, Biceps, and Triceps Lateral Head during the Lift task, with RMS reductions up to 64 % and large effect sizes. Perceived exertion slopes decreased across all tasks, with some instances showing stabilization or reduction during activity. Kinematic analysis indicated minimal impact on shoulder range of motion, with slight adjustments in internal/external rotation remaining within physiological norms. NASA-TLX scores suggested reduced physical demand and effort, and SUS responses indicated moderate usability with room for improvement. These findings demonstrate that soft exoskeletons can effectively unload muscles and reduce fatigue during prosthesis use, highlighting their potential to enhance endurance, task performance, and user comfort. Future work should extend assistance to additional joints and evaluate the system with upper-limb amputees in real-world scenarios.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Neural Systems and Rehabilitation Engineering
Published
2025-12-18
DOI
https://doi.org/10.1109/tnsre.2025.3646061
Primary Topic
Prosthetics and Rehabilitation Robotics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Mitigating Muscle Fatigue in Upper-Limb Prosthesis Users Through Exoskeletal Weight Compensation

Camilo A. R. Díaz, Marcela Múnera, Carlos A. Cifuentes, Laura De Arco et al.
IEEE Transactions on Neural Systems and Rehabilitation Engineering
Prosthetics and Rehabilitation Robotics
article

Mitigating Muscle Fatigue in Upper-Limb Prosthesis Users Through Exoskeletal Weight Compensation

Camilo A. R. Díaz, Marcela Múnera, Carlos A. Cifuentes, Laura De Arco, Marcelo E. V. Segatto, Ksawery Gusakowski
article en

Abstract

Prosthesis users often experience muscle fatigue and reduced control due to the weight of the device, contributing to high abandonment rates. This study investigates the effects of integrating a soft exoskeleton with a myoelectric prosthesis on upper-limb muscle fatigue and user experience. Nine non-disabled participants performed four functional tasks: drinking from a cup, using a Fork, lifting a box, and reaching overhead, using the prosthesis alone and in combination with the exoskeleton. Muscle activity was recorded via surface electromyography, and perceived exertion was measured using the Borg scale. Kinematics and workload were also assessed through motion capture and the NASA-TLX questionnaire. Usability was evaluated using the System Usability Scale (SUS). Results showed that exoskeleton assistance significantly reduced muscle activation, particularly in the Deltoid, Biceps, and Triceps Lateral Head during the Lift task, with RMS reductions up to 64 % and large effect sizes. Perceived exertion slopes decreased across all tasks, with some instances showing stabilization or reduction during activity. Kinematic analysis indicated minimal impact on shoulder range of motion, with slight adjustments in internal/external rotation remaining within physiological norms. NASA-TLX scores suggested reduced physical demand and effort, and SUS responses indicated moderate usability with room for improvement. These findings demonstrate that soft exoskeletons can effectively unload muscles and reduce fatigue during prosthesis use, highlighting their potential to enhance endurance, task performance, and user comfort. Future work should extend assistance to additional joints and evaluate the system with upper-limb amputees in real-world scenarios.

IEEE Transactions on Neural Systems and Rehabilitation EngineeringVol. 34
University of the West of England (GB), Universidade Federal do Espírito Santo (BR)
Openalex Percentile: Top 59%
Prosthetics and Rehabilitation Robotics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.