Adhesive tape for spatially resolved and sensitive detection of lead in dust using XRF

A method for rapidly and quantitatively measuring lead (Pb) in dust has been developed. Different types of wiping materials were tested. Due to its adhesive properties and flatness when folded, painter's tape effectively picks up dust and, when coupled with portable X-ray fluorescence (XRF) provides a rapid and sensitive measurement of Pb in dust. The tape can pick up approximately 0.095 g of dust, which is comparable to the amount of dust present in one square foot of a house that is vacuumed once a month (0.100 g). Dust in an area of 1 square foot was wiped up and a calibration curve was constructed by analyzing the folded tape on XRF (in ppm) <i>versus</i> the amount of Pb on the wipe that was determined by digestion and ICP-OES (in µg). Validation of this method revealed that when tested at each of the current EPA action levels for Pb dust (5 µg for floors, 40 µg for windowsills and 100 µg for window troughs), each of the false positive rates (FPR) was below 15% and each of the false negative rates (FNR) was below 5%. Thus, at these lower Pb levels, Painter's tape with XRF measurement could allow for spatially-resolved, rapid determination of Pb in dust on site, which has been a long-standing need.

Authors

Institutions

Publication Details

Journal
Analytical Methods
Published
2025-11-21
DOI
https://doi.org/10.1039/d5ay01275a
Primary Topic
Heavy Metal Exposure and Toxicity
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Adhesive tape for spatially resolved and sensitive detection of lead in dust using XRF

B.C. Cho, A. C. B. Wicks, Marya Lieberman, Zhutian Zhang et al.
Analytical Methods
Heavy Metal Exposure and Toxicity
article

Adhesive tape for spatially resolved and sensitive detection of lead in dust using XRF

B.C. Cho, A. C. B. Wicks, Marya Lieberman, Zhutian Zhang, Ornella Joseph, D. Kwon, Vikrant Jandev, Devena Sammanasu
article en

Abstract

A method for rapidly and quantitatively measuring lead (Pb) in dust has been developed. Different types of wiping materials were tested. Due to its adhesive properties and flatness when folded, painter's tape effectively picks up dust and, when coupled with portable X-ray fluorescence (XRF) provides a rapid and sensitive measurement of Pb in dust. The tape can pick up approximately 0.095 g of dust, which is comparable to the amount of dust present in one square foot of a house that is vacuumed once a month (0.100 g). Dust in an area of 1 square foot was wiped up and a calibration curve was constructed by analyzing the folded tape on XRF (in ppm) <i>versus</i> the amount of Pb on the wipe that was determined by digestion and ICP-OES (in µg). Validation of this method revealed that when tested at each of the current EPA action levels for Pb dust (5 µg for floors, 40 µg for windowsills and 100 µg for window troughs), each of the false positive rates (FPR) was below 15% and each of the false negative rates (FNR) was below 5%. Thus, at these lower Pb levels, Painter's tape with XRF measurement could allow for spatially-resolved, rapid determination of Pb in dust on site, which has been a long-standing need.

Analytical MethodsVol. 18(6)
University of Notre Dame (US), Earlham College (US), Holy Cross College (US)
U.S. Department of Housing and Urban Development, University of Notre Dame
Openalex Percentile: Top 50%
Heavy Metal Exposure and Toxicity
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.