Determining optimal GTV‐to‐PGTV margins for CT‐guided dose‐escalated radiotherapy with daily image guidance in locally advanced rectal cancer
A 6 mm isotropic GTV to PGTV margin provides adequate target coverage for most middle- and lower-rectal tumors while reducing OAR overlap. This finding could facilitate safer dose escalation while maintaining target coverage. However, larger margins may be necessary for smaller tumors or those located in the high rectum.