Experimental classification of dynamic speckle regimes: insights from controlled rotational diffuser measurements

Dynamic speckle phenomena, arising from coherent light scattering on moving diffuse surfaces, are widely used for motion analysis in fields such as biomedical imaging and industrial inspection. However, the classification of dynamic speckle regimes remains challenging, particularly in understanding their distinct temporal and spatial behaviors across various velocity ranges. In this study, we introduce a comprehensive framework for categorizing speckle dynamics into three regimes: frozen, intermediate, and fully decorrelated. Each exhibits distinct temporal decorrelation properties, with direct consequences for motion quantification. To validate this framework, we designed an experimental setup comprising a coherent laser source, a controlled rotational diffuser as the moving scattering surface, and a high-resolution imaging system. This configuration enables precise control of speckle motion and systematic sampling of a wide velocity range. The experimental results reveal consistent and reproducible transitions between the three regimes, in strong agreement with the predicted contrast-velocity relationships. Our findings underscore the practical significance of this classification. In particular, they demonstrate that system performance depends critically on the regime in which measurements are made. Accurate velocity estimation requires adapting the acquisition strategy to the specific characteristics of each regime, including frame rate and exposure time. The intermediate regime, where contrast varies only weakly with velocity, should be avoided in system design due to its poor sensitivity. In addition to clarifying speckle dynamics, this framework enables the optimization of imaging system parameters by ensuring that measurements are performed in regimes where contrast is most sensitive to motion.

Authors

Institutions

Publication Details

Journal
Journal of the Optical Society of America A
Published
2025-08-27
DOI
https://doi.org/10.1364/josaa.571395
Primary Topic
Thermoregulation and physiological responses
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Experimental classification of dynamic speckle regimes: insights from controlled rotational diffuser measurements

Xavier Orlik, Enric Garcia‐Caurel, Elise Colin‐Koeniguer, Aurélien Plyer et al.
Journal of the Optical Society of America A
Thermoregulation and physiological responses
article

Experimental classification of dynamic speckle regimes: insights from controlled rotational diffuser measurements

Xavier Orlik, Enric Garcia‐Caurel, Elise Colin‐Koeniguer, Aurélien Plyer, Razvigor Ossikovski
article en

Abstract

Dynamic speckle phenomena, arising from coherent light scattering on moving diffuse surfaces, are widely used for motion analysis in fields such as biomedical imaging and industrial inspection. However, the classification of dynamic speckle regimes remains challenging, particularly in understanding their distinct temporal and spatial behaviors across various velocity ranges. In this study, we introduce a comprehensive framework for categorizing speckle dynamics into three regimes: frozen, intermediate, and fully decorrelated. Each exhibits distinct temporal decorrelation properties, with direct consequences for motion quantification. To validate this framework, we designed an experimental setup comprising a coherent laser source, a controlled rotational diffuser as the moving scattering surface, and a high-resolution imaging system. This configuration enables precise control of speckle motion and systematic sampling of a wide velocity range. The experimental results reveal consistent and reproducible transitions between the three regimes, in strong agreement with the predicted contrast-velocity relationships. Our findings underscore the practical significance of this classification. In particular, they demonstrate that system performance depends critically on the regime in which measurements are made. Accurate velocity estimation requires adapting the acquisition strategy to the specific characteristics of each regime, including frame rate and exposure time. The intermediate regime, where contrast varies only weakly with velocity, should be avoided in system design due to its poor sensitivity. In addition to clarifying speckle dynamics, this framework enables the optimization of imaging system parameters by ensuring that measurements are performed in regimes where contrast is most sensitive to motion.

Journal of the Optical Society of America AVol. 42(10)
Centre National de la Recherche Scientifique (FR), École Polytechnique (FR), Université Fédérale de Toulouse Midi-Pyrénées (FR), Université Paris Cité (FR), Université Paris-Saclay (FR), Laboratoire de Physique des Interfaces et des Couches Minces (FR)
Openalex Percentile: Top 49%
Thermoregulation and physiological responses
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.