Direct detection of SABRE-SHEATH hyperpolarization and spin-lattice relaxation of [1-13C]pyruvate

Nuclear magnetism is typically investigated by perturbing the spin system with radio frequency pulses, but low polarization and detection using induction coils limit direct access to the longitudinal magnetization. The hyperpolarization technique SABRE-SHEATH requires ultra-low magnetic fields for spin order transfer; consequently, SQUID sensors with a frequency-independent sensitivity are well-suited for unperturbed detection in this regime. We demonstrate direct observation of hyperpolarization build up (T<sub>B</sub>) and spin lattice relaxation (T<sub>1</sub>) in [1-<sup>13</sup>C]pyruvate, hyperpolarized with SABRE-SHEATH at 150 nT and 500 nT. The values for T<sub>B</sub> of 36 s and 26 s and T<sub>1</sub> of 40 s and 43 s, respectively, suggests a shift in dominant polarization transfer efficacy or complexes, highlighting the method's merit in characterizing hyperpolarization pathways. Moreover, as demand for hyperpolarized probes in metabolic imaging continues to grow, the exceptional time resolution makes direct detection a valuable tool for understanding and optimizing polarization dynamics and reactor designs.

Authors

Institutions

Publication Details

Journal
Communications Chemistry
Published
2025-12-20
DOI
https://doi.org/10.1038/s42004-025-01851-1
Primary Topic
Advanced NMR Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Direct detection of SABRE-SHEATH hyperpolarization and spin-lattice relaxation of [1-13C]pyruvate

John Z. Myers, Kai Buckenmaier, Markus Plaumann, Andrey N. Pravdivtsev et al.
Communications Chemistry
Advanced NMR Techniques and Applications
article

Direct detection of SABRE-SHEATH hyperpolarization and spin-lattice relaxation of [1-13C]pyruvate

John Z. Myers, Kai Buckenmaier, Markus Plaumann, Andrey N. Pravdivtsev, Rainer Körber
article en

Abstract

Nuclear magnetism is typically investigated by perturbing the spin system with radio frequency pulses, but low polarization and detection using induction coils limit direct access to the longitudinal magnetization. The hyperpolarization technique SABRE-SHEATH requires ultra-low magnetic fields for spin order transfer; consequently, SQUID sensors with a frequency-independent sensitivity are well-suited for unperturbed detection in this regime. We demonstrate direct observation of hyperpolarization build up (T<sub>B</sub>) and spin lattice relaxation (T<sub>1</sub>) in [1-<sup>13</sup>C]pyruvate, hyperpolarized with SABRE-SHEATH at 150 nT and 500 nT. The values for T<sub>B</sub> of 36 s and 26 s and T<sub>1</sub> of 40 s and 43 s, respectively, suggests a shift in dominant polarization transfer efficacy or complexes, highlighting the method's merit in characterizing hyperpolarization pathways. Moreover, as demand for hyperpolarized probes in metabolic imaging continues to grow, the exceptional time resolution makes direct detection a valuable tool for understanding and optimizing polarization dynamics and reactor designs.

Communications ChemistryVol. 9(1)
Physikalisch-Technische Bundesanstalt (DE), University Hospital Schleswig-Holstein (DE), Max Planck Institute for Biological Cybernetics (DE), Institute of Molecular Biology (DE), University of Lübeck (DE), Otto-von-Guericke-Universität Magdeburg (DE)
Openalex Percentile: Top 63%
Advanced NMR Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.