Second-Generation Hydrogel Coils for Transcatheter Arterial Embolization of Acute Arterial Bleeding in the Body Trunk

IntroductionFirst-generation hydrogel coils have been shown to reduce the risk of recanalization due to their expansion properties. However, their clinical use has been limited by coil stiffness and time constraints for deployment. Recently developed second-generation hydrogel coils are softer and offer improved deliverability. This study aimed to evaluate their feasibility and effectiveness in transcatheter arterial embolization (TAE) for acute arterial bleeding in the body trunk.MethodsThis retrospective study included 24 TAE procedures performed in 23 patients (15 men, 8 women; median age, 72 years; range, 14-88 years) between March 2019 and November 2024. Indications for TAE included iatrogenic injury (n = 7), gastrointestinal bleeding (n = 5), trauma (n = 3), aneurysm rupture (n = 3), tumor invasion (n = 3), and others (n = 3). Second-generation hydrogel coils were used in all cases, comprising a median of 78% (range, 13-100%) of the total coil length. Technical success was defined as complete occlusion of the target artery on digital subtraction angiography. Clinical success was defined as the absence of rebleeding within 24 h of embolization.ResultsAnemia, hemorrhagic shock, and coagulopathy were present before TAE in 92% (22/24), 21% (5/24), and 25% (6/24) of procedures, respectively. The mean total coil length was 40 cm (range, 4-127 cm), and the mean procedure time was 111 min (range, 58-207 min). Both technical and clinical success rates were 100% (24/24). One complication (4%) occurred: transient liver dysfunction in a patient treated for hepatic artery bleeding.ConclusionsTAE using second-generation hydrogel coils showed high technical and clinical success rates, indicating that these coils may be a feasible and effective option for managing acute arterial hemorrhage in the body trunk.

Authors

Institutions

Publication Details

Journal
Vascular and Endovascular Surgery
Published
2025-12-20
DOI
https://doi.org/10.1177/15385744251409969
Primary Topic
Vascular Anomalies and Treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Second-Generation Hydrogel Coils for Transcatheter Arterial Embolization of Acute Arterial Bleeding in the Body Trunk

Hiroaki Okada, Yuta Nakano, Yuki Maruchi, Kojiro Suzuki et al.
Vascular and Endovascular Surgery
Vascular Anomalies and Treatments
article

Second-Generation Hydrogel Coils for Transcatheter Arterial Embolization of Acute Arterial Bleeding in the Body Trunk

Hiroaki Okada, Yuta Nakano, Yuki Maruchi, Kojiro Suzuki, Masashi Shimohira, Takahiro Yamamoto, Nozomu Matsunaga, Akiko Narita, Shuji Ikeda, Toshinobu Saga, Kyohei Takahata, Shin‐ichi Ozaki
article en

Abstract

IntroductionFirst-generation hydrogel coils have been shown to reduce the risk of recanalization due to their expansion properties. However, their clinical use has been limited by coil stiffness and time constraints for deployment. Recently developed second-generation hydrogel coils are softer and offer improved deliverability. This study aimed to evaluate their feasibility and effectiveness in transcatheter arterial embolization (TAE) for acute arterial bleeding in the body trunk.MethodsThis retrospective study included 24 TAE procedures performed in 23 patients (15 men, 8 women; median age, 72 years; range, 14-88 years) between March 2019 and November 2024. Indications for TAE included iatrogenic injury (n = 7), gastrointestinal bleeding (n = 5), trauma (n = 3), aneurysm rupture (n = 3), tumor invasion (n = 3), and others (n = 3). Second-generation hydrogel coils were used in all cases, comprising a median of 78% (range, 13-100%) of the total coil length. Technical success was defined as complete occlusion of the target artery on digital subtraction angiography. Clinical success was defined as the absence of rebleeding within 24 h of embolization.ResultsAnemia, hemorrhagic shock, and coagulopathy were present before TAE in 92% (22/24), 21% (5/24), and 25% (6/24) of procedures, respectively. The mean total coil length was 40 cm (range, 4-127 cm), and the mean procedure time was 111 min (range, 58-207 min). Both technical and clinical success rates were 100% (24/24). One complication (4%) occurred: transient liver dysfunction in a patient treated for hepatic artery bleeding.ConclusionsTAE using second-generation hydrogel coils showed high technical and clinical success rates, indicating that these coils may be a feasible and effective option for managing acute arterial hemorrhage in the body trunk.

Vascular and Endovascular Surgery
Aichi Medical University (JP)
Openalex Percentile: Top 38%
Vascular Anomalies and Treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.