Diagnostic significance of lung ultrasound in evaluation of heart failure: A cross-sectional study in comparison with clinical assessment, proBNP, chest X-ray, and echocardiography
Lung ultrasound (LUS) detection of B-lines is a useful bedside tool for evaluating pulmonary congestion in acute heart failure. This study aimed to assess the diagnostic performance of LUS compared to clinical assessment, N-terminal pro-B-type natriuretic peptide, chest X-ray, and echocardiography in patients with systolic heart failure. A cross-sectional study was conducted on 50 patients diagnosed with heart failure based on Framingham criteria and confirmed by echocardiography at Al Yarmook General Teaching Hospital, Baghdad (May-October 2021). LUS was performed across 16 lung zones to detect B-lines. Diagnostic validity was assessed using receiver operating characteristic curve analysis, referencing ejection fraction ≤ 30%, mitral inflow to annular velocity ratio (E/eé) ≥ 15, and N-terminal pro-B-type natriuretic peptide > 450 pg/mL. From the 16 lung zones, zone number 1 in the left side was with B lines findings in all (46) ultrasound positive patients, followed by zone number 1 in the right side were with positive B lines in (44) patients. Using ≥10 lung zones with B-lines as the diagnostic cutoff for acute heart failure, LUS demonstrated a sensitivity of 64.7% and specificity of 63.6% when ejection fraction ≤30% was used as the reference standard, and a sensitivity of 63.6% and specificity of 88.2% when E/e' ≥ 15 was used as the reference. While using pro-B-type natriuretic peptide > 450 pg/mL as reference for acute heart failure it showed that 4 lung zones with B lines will be the cutoff value with a sensitivity of 86.67% and specificity of 80.00%. Lung sonography could be considered a reliable tool for the assessment of pulmonary congestion in patients with acute heart failure. Using 10 lung zones with B-lines by ultrasound as a cutoff value for the diagnosis of acute heart failure. However, its accuracy may be limited by operator dependency and small sample size.
Authors
- Ahmed Dheyaa Al‐Obaidi
- Hashim Talib Hashim (ORCID: https://orcid.org/0000-0001-6155-7302)
- Abbas Al-Sharifi
- Marafi Jammaa Ahmed (ORCID: https://orcid.org/0009-0000-5032-8627)
- Marwah Algodi
- Aya Ahmed Shimal
- Ahmed Raed Alrubaye
Institutions
- University of Baghdad (IQ)
- Mustansiriyah University (IQ)
- Baghdad Medical City (IQ)
- University of Kerbala (IQ)
- University of Bahri (SD)
- Jersey Shore University Medical Center (US)
- University of Warith Al-Anbiyaa
Publication Details
- Journal
- Medicine
- Published
- 2025-12-19
- DOI
- https://doi.org/10.1097/md.0000000000046722
- Primary Topic
- Ultrasound in Clinical Applications
- Type
- article
- Field-Weighted Citation Impact
- 0.00