The detrimental effects of endovascular aneurysm repair on aortic compliance

Objective: Endovascular aneurysm repair (EVAR) constitutes the cornerstone of contemporary abdominal aortic aneurysm (AAA) treatment, owing to superior short-term outcomes in comparison with open surgical repair (OSR).However, this difference is offset by unfavorable long-term outcomes.EVAR may detrimentally affect aortic compliance, with significant subsequent consequences.We sought to elucidate the natural history of this phenomenon. Methods:We conducted a nonrandomized, prospective study of 140 consecutive patients undergoing elective EVAR or OSR for abdominal aortic aneurysm.Aortic stiffness was measured preoperatively (T0), within 1 week of the operation (T1), 4 to 6 weeks (T2), and at 1 year (T3), using a validated noninvasive device (Vicorder) to measure carotid-femoral pulse wave velocity (cfPWV) and brachial-femoral pulse wave velocity (bfPWV), as well as central pulse pressure.Repeated measures analysis of variance was applied to the hemodynamic measurements to quantify changes along time.Results: Of 140 patients, 130 (93%) underwent EVAR.EVAR resulted in a significant increase in carotid-femoral pulse wave velocity (T0, 9.9 1.3 m/s; T1, 11.0 1.6 m/s; T2, 12.2 3.8 m/s; and T3, 12.5 2.6 m/s; P < .05for the comparison with T0), bfPWV (T0, 34.6 12 mm Hg; T1, 40.4 12.4 mm Hg; T2, 44.2 14.6 mm Hg; and T3, 44.3 12.6 mm Hg; P < .05for the comparison with T0), and central pulse pressure (T0, 59 12 mm Hg; T1, 61 12 mm Hg; T2, 63 13; and T3, 64 12 mm Hg mm Hg; P < .05for the comparison of T2 and T3 with T0).There were no significant differences across all timepoints for those having OSR. Conclusions:In this study, the first to use bfPWV in this context, EVAR, but not OSR, significantly decreased aortic compliance, not only immediately post intervention, but steadily over 1 year.(JVS-Vascular Insights 2026;:100344.

Authors

Institutions

Publication Details

Journal
JVS-Vascular Insights
Published
2025-12-20
DOI
https://doi.org/10.1016/j.jvsvi.2025.100344
Primary Topic
Cardiovascular Health and Disease Prevention
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The detrimental effects of endovascular aneurysm repair on aortic compliance

Dimitrios Vlastos, Anastasios Minas, Ignatios Ikonomidis, John S M Houghton et al.
JVS-Vascular Insights
Cardiovascular Health and Disease Prevention
article

The detrimental effects of endovascular aneurysm repair on aortic compliance

Dimitrios Vlastos, Anastasios Minas, Ignatios Ikonomidis, John S M Houghton, Matthew J. Bown, Vimal J. Gokani, Emily Salt, Stefan Klimach, A. Siddique, Athanasios N. Saratzis, Rob D. Sayers
article en

Abstract

Objective: Endovascular aneurysm repair (EVAR) constitutes the cornerstone of contemporary abdominal aortic aneurysm (AAA) treatment, owing to superior short-term outcomes in comparison with open surgical repair (OSR).However, this difference is offset by unfavorable long-term outcomes.EVAR may detrimentally affect aortic compliance, with significant subsequent consequences.We sought to elucidate the natural history of this phenomenon. Methods:We conducted a nonrandomized, prospective study of 140 consecutive patients undergoing elective EVAR or OSR for abdominal aortic aneurysm.Aortic stiffness was measured preoperatively (T0), within 1 week of the operation (T1), 4 to 6 weeks (T2), and at 1 year (T3), using a validated noninvasive device (Vicorder) to measure carotid-femoral pulse wave velocity (cfPWV) and brachial-femoral pulse wave velocity (bfPWV), as well as central pulse pressure.Repeated measures analysis of variance was applied to the hemodynamic measurements to quantify changes along time.Results: Of 140 patients, 130 (93%) underwent EVAR.EVAR resulted in a significant increase in carotid-femoral pulse wave velocity (T0, 9.9 1.3 m/s; T1, 11.0 1.6 m/s; T2, 12.2 3.8 m/s; and T3, 12.5 2.6 m/s; P < .05for the comparison with T0), bfPWV (T0, 34.6 12 mm Hg; T1, 40.4 12.4 mm Hg; T2, 44.2 14.6 mm Hg; and T3, 44.3 12.6 mm Hg; P < .05for the comparison with T0), and central pulse pressure (T0, 59 12 mm Hg; T1, 61 12 mm Hg; T2, 63 13; and T3, 64 12 mm Hg mm Hg; P < .05for the comparison of T2 and T3 with T0).There were no significant differences across all timepoints for those having OSR. Conclusions:In this study, the first to use bfPWV in this context, EVAR, but not OSR, significantly decreased aortic compliance, not only immediately post intervention, but steadily over 1 year.(JVS-Vascular Insights 2026;:100344.

JVS-Vascular InsightsVol. 4
Nottingham University Hospitals NHS Trust (GB), University of Leicester (GB), National and Kapodistrian University of Athens (GR), Charing Cross Hospital (GB), University Hospitals of Leicester NHS Trust (GB), University Hospitals of Derby and Burton NHS Foundation Trust (GB), NIHR Leicester Biomedical Research Centre (GB)
British Heart Foundation
Openalex Percentile: Top 42%
Cardiovascular Health and Disease Prevention
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.